32

New Holland 32 – TMF: Ground Speed Signal Failure

Issue description

The TMF (Instrumentation Controller) is not receiving a valid signal from the ground speed sensor. This signal is crucial for accurate speed display, automatic transmission shifting, and precise application rates for implements. The failure indicates a problem with the signal being received or processed, which could stem from a faulty sensor, a damaged wiring harness, or the controller itself.

Applies to these machines

  • TM115
  • TM120
  • TM125
  • TM130
  • TM135
  • TM140
  • TM150
  • TM155
  • TM165
  • TM175
  • TM190
  • TS90
  • TS100
  • TS110
  • TS115
  • TS100A
  • TS110A
  • TS115A
  • TS125A
  • TS135A
  • T6010
  • T6020
  • T6030
  • T6040
  • T6050
  • T6060
  • T6070
  • T6080
  • T6090
  • T7000 Series
  • T8000 Series
  • TG255
  • C175
  • C185
  • C190
  • C227
  • C232
  • C234
  • C237
  • C238
  • C245
  • C327
  • C332
  • C334
  • C337
  • C338
  • C345

Check the cause

  1. Visually inspect the ground speed sensor and its wiring for obvious signs of damage, frayed wires, loose connections, or corrosion

  2. Check for shorts to ground by disconnecting the sensor and using a multimeter to check continuity between each pin on the component side and chassis ground

  3. Check for short circuits by testing continuity between the pins on the component side of the disconnected sensor

  4. Check for open circuits by testing continuity along the harness from the sensor connector to the instrumentation controller connector

  5. Check voltage and resistance values for the sensor and circuit against the specific model's service manual

  6. Clear fault codes after any repair attempt and operate the machine to see if the code reappears

Repair steps

  1. Identify and locate the ground speed sensor

    The sensor can be a radar unit (often called a 'true ground speed sensor') or a wheel speed sensor. Its location varies; it could be on the transmission housing, flywheel bell housing, or rear axle assembly.

  2. Perform diagnostic checks

    Follow the diagnostic steps outlined to isolate the fault to the sensor, wiring, or controller.

  3. Repair wiring harness

    If the wiring harness is damaged, repair the affected wires, ensuring connections are secure and insulated.

  4. Replace ground speed sensor

    If the sensor is identified as faulty, replace it with a new one.

  5. Clear codes and test

    Once the repair is complete, clear the fault code from the system and test the tractor to ensure the speedometer and other related functions are operating correctly.

Parts you might need

(4)
  • Interchanges with 228760A1. Radar sensor that measures speed relative to the ground.

  • Transmission Speed RPM Flywheel Sensor

    85802950

    Interchanges with 83996843, F0NN11N008AA, F0NN11N008AB. Inductive sensor.

  • Interchanges with 86027316. Inductive sensor.

  • Interchanges with 86593627. Inductive sensor.

Get help to fix this fault by requesting a quote