New Holland 3319 – DCU: Dosage Control Unit Error: Urea Level in the Tank is Below 5%
Issue description
The Dosage Control Unit (DCU) has detected via the fluid level sensor that the Diesel Exhaust Fluid (DEF/AdBlue) level in the tank has dropped below 5% of its capacity. This condition triggers a warning to the operator and, if not addressed, can lead to engine power reduction (derate) or limitations on engine restarts.
Applies to these machines
16 machines- T6
- T7
- T8
- T9
- CR
- CX
- Magnum
- Maxxum
- Puma
- Steiger
- 5130
- 6130
- 7130
- 7230
- 8230
- 9230
Check the cause
Visually inspect the DEF tank to confirm if the fluid level is actually low.
Use a refractometer to verify that the DEF concentration is at the correct level (typically 32.5%).
Check for associated SCR system fault codes (e.g., 19101, 19102, 19094) that indicate an electrical short or open circuit in the level sensor, pointing to an electrical issue rather than low fluid.
Inspect the wiring harness and connectors between the DEF tank sensor and the DCU for damage, corrosion, water ingress, loose pins, or crystalline DEF residue.
Test the DEF level sensor resistance using a multimeter. Compare readings to specification values based on fluid level (e.g., 58mm: 91 Ohms, 79mm: 601 Ohms, 100mm: 1.111 K Ohms, 142mm: 2.131 K Ohms, 205mm: 3.711 K Ohms, 250mm: 4.631 K Ohms, 350mm: 6.671 K Ohms, 500mm: 11.551 K Ohms).
Repair steps
Refill DEF tank
If the tank is physically low, refill with new, uncontaminated DEF meeting ISO 22241 standards. Clear the fault codes and operate the machine to confirm the fault does not return.
Repair wiring harness
If wiring issues or corrosion are found during inspection, repair or replace the damaged sections of the harness. Ensure all connectors are clean, secure, and free of corrosion.
Replace DEF level sensor
If the sensor fails the resistance test, drain the DEF tank below the sensor assembly. Disconnect and mark electrical connectors and fluid lines. Remove the failed sensor assembly, install the new unit, torque fasteners to spec, reconnect lines, refill the tank, and clear codes.
Replace Dosing Control Unit (DCU)
If the sensor, wiring, and DEF level are all confirmed to be good, the DCU itself may be faulty. Replace the DCU. Note that this module may require software programming to the vehicle after installation.
Parts you might need
(2)Manufactured by Bosch. Replacement may require software programming.
DEF Level Sensor / Sender
Often integrated with the DEF tank heater and sender unit assembly. Provides level and temperature readings to the DCU.
Get help to fix this fault by requesting a quote