New Holland 3386 – New Holland Engine: Increase Fan Speed Driver Circuit Open or Short to Ground
Issue description
The fault code indicates an issue with the increase fan speed driver circuit, specifically an open circuit or a short to ground. This can prevent the fan from operating correctly or cause improper control of its speed.
Check the cause
The wiring associated with the increase fan speed driver circuit
Connections and terminals related to the increase fan speed driver circuit
The component identified by this code for signs of damage or wear
Repair steps
Inspect
Inspect the wiring and connections of the increase fan speed driver circuit for any visible damage, corrosion, or disconnection.
Test
Test the circuit for continuity and resistance using a multimeter, following the service manual procedures.
Replace
If damage is found, replace the affected wiring or component as needed.
Parts you might need
(0)Get help to fix this fault by requesting a quote