3386

New Holland 3386 – New Holland Engine: Increase Fan Speed Driver Circuit Open or Short to Ground

Issue description

The fault code indicates an issue with the increase fan speed driver circuit, specifically an open circuit or a short to ground. This can prevent the fan from operating correctly or cause improper control of its speed.

Check the cause

  1. The wiring associated with the increase fan speed driver circuit

  2. Connections and terminals related to the increase fan speed driver circuit

  3. The component identified by this code for signs of damage or wear

Repair steps

  1. Inspect

    Inspect the wiring and connections of the increase fan speed driver circuit for any visible damage, corrosion, or disconnection.

  2. Test

    Test the circuit for continuity and resistance using a multimeter, following the service manual procedures.

  3. Replace

    If damage is found, replace the affected wiring or component as needed.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes