New Holland 3550 – ECU: Signal Ratio Fault of Humidity Sensor - Signal Ratio Below Allowable Limit

Issue description

The system has detected an abnormally low signal from the humidity sensor (grain moisture sensor assembly) located in the clean grain elevator. The signal ratio is below the allowable limit, meaning the voltage or data reading is outside the expected operational range. This indicates a potential malfunction in the sensor or its circuitry, which will affect the accuracy of humidity readings and the proper operation of the yield monitoring system.

Applies to these machines

  • CR6.80
  • CR6.90
  • CR6090
  • CR7.90
  • CR7090
  • CR8.90
  • CR8080
  • CR8090
  • CR9.90
  • CR10.90
  • CR920
  • CR940
  • CR960
  • CR970
  • CR9060
  • CR9070
  • CR9080
  • CR9090
  • CX8070
  • CX8080
  • CX8090

Check the cause

  1. Check for other active fault codes (e.g., 3557 and 3558, which indicate water saturation).

  2. Inspect the dedicated 5-amp fuse for the moisture sensor assembly, especially if the machine has been in storage.

  3. Visually inspect the wiring harness and connectors leading to the moisture sensor for damage, chafing, or corrosion.

  4. Remove the sensor cover and clean the sensing plate/fin inside using brake cleaner or acetone to remove debris, mud, or green material buildup.

  5. Inspect the sensor assembly's small auger and housing to ensure it is clean, free of rust, and not blocked by debris.

  6. Verify that the sensor's ground strap is clean and securely attached to the chassis.

  7. Monitor live sensor voltage in the diagnostic menu; a reading of zero or an unchanging value points to a sensor or wiring failure.

Repair steps

  1. Access the moisture sensor

    Locate the sensor on the side of the clean grain elevator, typically held in place by two wing nuts.

  2. Disconnect and remove sensor

    Disconnect the electrical connector, remove the wing nuts, and carefully pull the sensor assembly out of its housing.

  3. Test the auger motor

    Bypass the control system to test the small auger motor directly. If applying power blows the fuse, the motor is shorted.

  4. Replace faulty components

    Replace the entire moisture sensor assembly, or replace individual components like the electric motor or printed circuit board if available separately.

  5. Install new sensor

    Install the new sensor assembly, ensuring it is seated correctly, and securely reconnect the electrical harness.

  6. Calibrate the sensor

    Perform a moisture calibration through the combine's display monitor as specified in the operator's manual.

Parts you might need

(7)
  • Replaces 87534936. Fits CR/CX series and Case IH. Includes sensor, motor, auger, and housing.

  • Alternate OEM part number for complete assembly.

  • Moisture Sensor Assembly

    84435210

    Alternate OEM part number for complete assembly.

  • Alternate OEM part number for complete assembly.

  • Individual auger motor for the moisture sensor assembly.

  • Individual PCB for the moisture sensor assembly.

  • Fits New Holland T7/T8 tractors, CR/CX combines, and Case IH equivalents. The sensor measures approximately 70.71 mm in length.

Get help to fix this fault by requesting a quote

Browse other New Holland codes