New Holland 3550 – Engine ECM: Humidity Sensor Signal Ratio Failure
Issue description
The engine control module (ECM) has detected that the humidity sensor is reporting a signal ratio below the established lower limit. This indicates the sensor is providing a reading outside its expected operational range, pointing to a potential issue with the sensor itself, its wiring, or its connectors, which affects its ability to provide accurate readings for the engine's air intake and emissions control (SCR) systems.
Applies to these machines
18 machines- T7.170
- T7.185
- T7.200
- T7.210
- T7.230
- T7.245
- T7.260
- T8.275
- T8.300
- T8.330
- T8.350
- T8.360
- T8.380
- T8.390
- T8.410
- T8.420
- Magnum 235
- Magnum 340
Check the cause
Visually inspect the humidity sensor, connector, and wiring harness for physical damage, corrosion, or loose connections.
Check for related fault codes, particularly ambient air temperature sensor codes (3517, 3518, 3519) or sensor saturation codes (3557, 3558).
Test the wiring harness for continuity and shorts to power or ground, and ensure electrical connectors are clean and dry.
Verify battery and charging system voltage, as low system voltage can trigger erroneous sensor faults.
Check the sensor for contamination or blockage from debris, and inspect the associated circuit fuse.
If saturation codes 3557 or 3558 are present, investigate the air intake system for potential sources of water ingress.
Repair steps
Park machine safely
Park the machine on a level surface, shut down the engine, and remove the key.
Locate the sensor
Find the humidity sensor on the air intake tube between the air filter and the turbocharger, often near the air restriction sensor.
Remove the faulty sensor
Disconnect the electrical harness connector. If necessary for access, disengage the hose clamps and remove the section of the air intake tube where the sensor is mounted, then remove the sensor.
Install the new sensor
Install the new humidity sensor into the air intake tube, ensuring it is seated correctly. Reinstall the intake tube and secure clamps if removed, then reconnect the electrical harness.
Clear fault codes
Use a diagnostic tool to clear the fault code from the ECM's memory.
Verify repair
Start the engine and allow it to run for several minutes. Re-check for any active fault codes to ensure the repair was successful. Note that a calibration of the new sensor may be required in some systems.
Parts you might need
(4)- Humidity Sensor87482355
Primary CNH part for T-series tractors and CX-series excavators. Verify fitment by serial number.
- Humidity Sensor87564761
Alternative sensor part number for similar applications.
- Humidity Sensor84565657
Alternative sensor part number for similar applications.
- Moisture Sensor47901240
Moisture sensor typically used for combines.
Get help to fix this fault by requesting a quote