3609
New Holland 3609: Urea Quality and Urea Level Warnings
Issue description
The system has detected warnings related to urea quality and urea level. This may indicate an issue with the urea supply or its condition.
Check the cause
Urea tank level
Urea quality
Urea supply line
Repair steps
Check urea tank level
Verify that the urea tank contains sufficient urea and that the level is within the normal operating range.
Inspect urea quality
Ensure that the urea used meets the required specifications and is not contaminated or degraded.
Examine urea supply line
Check for any blockages, leaks, or damage in the urea supply line that could affect the flow or quality of urea.
Parts you might need
(0)Get help to fix this fault by requesting a quote