New Holland 3824 – ECU: Throttle Valve Actuator Short to Ground

Issue description

The Engine Control Unit (ECU) has detected a short circuit to ground on the electrical circuit for the Throttle Valve Actuator (TVA). Specifically, the fault is located on the wire connected to pin A34 of the engine's 60-pin connector, which corresponds to the second output (Out2) for the H-bridge controlling the throttle valve. This condition diverts the electrical signal to the vehicle's ground, preventing the throttle valve from operating as commanded and leading to engine performance issues.

Applies to these machines

  • T4.55
  • T4.65
  • T4.75
  • T4.85
  • T4.95
  • T4.105
  • T4.115
  • T4S.55
  • T4S.65
  • T4S.75
  • T5.75
  • T5.85
  • T5.95
  • T5.105
  • T5.115
  • PowerStar 75
  • PowerStar 90
  • PowerStar 100
  • PowerStar 110
  • PowerStar 120
  • B90B
  • B95B
  • B100C
  • B110C
  • L221
  • L228
  • L230
  • C232
  • C238
  • Farmall 55C
  • Farmall 115C
  • Farmall 55A
  • Farmall 115A
  • 580N
  • 580Super N
  • TR310
  • TV370

Check the cause

  1. Check battery voltage (ensure 12.6V) and verify main ground straps to the chassis are clean and tight, as low voltage can trigger erroneous codes.

  2. Visually inspect the wiring harness between the ECU and the Throttle Valve Actuator for chafing, cuts, melting, or corrosion.

  3. Disconnect and inspect connectors at the ECU (60-pin connector) and the Throttle Valve Actuator for corrosion, moisture, or damaged pins (ensure pin A34 is secure and not pushed back).

  4. Perform a continuity to ground test on the harness side of pin A34 to a known good chassis ground (should read as an open circuit/infinite resistance).

  5. Perform an internal short test on the actuator by measuring resistance between the actuator's A34 corresponding pin and its ground pin or casing.

Repair steps

  1. Isolate the fault

    Based on diagnostic checks, determine whether the short circuit to ground is located within the wiring harness or is internal to the Throttle Valve Actuator.

  2. Repair wiring harness

    If the fault is in the wiring harness, repair the damaged section of the wire connected to pin A34 or replace the affected harness section. Ensure all repairs are properly insulated and protected from future damage.

  3. Replace Throttle Valve Actuator

    If diagnostic tests confirm the Throttle Valve Actuator is internally shorted, replace the actuator assembly, as it is not a serviceable component.

  4. Perform idle relearn procedure

    Turn the ignition to the 'ON' position (without starting) for a few seconds, turn it off, and repeat. Then start the engine and allow it to idle for 5-10 minutes to let the ECU recalibrate to the new component.

  5. Clear fault codes

    Use a diagnostic tool to clear fault code 3824 from the ECU and verify that the code does not return.

Parts you might need

(9)
  • For FPT F5 3.4L engines. Cross-reference part numbers: 5801445778, 5801831821.

  • Verify exact part number using machine serial number

  • Actuator / Throttle Motor

    84036177

    Verify exact part number using machine serial number

  • Actuator

    5802084296

    Verify exact part number using machine serial number

  • Actuator51474193

    Verify exact part number using machine serial number

  • Throttle Control

    87528964

    Verify exact part number using machine serial number

  • Throttle Control

    84374767

    For Compact Track Loaders. May be a mechanical pedal assembly without the electronic actuator.

  • Throttle Control

    47409019

    For Compact Track Loaders.

  • Actuator84525638

    Verify fitment by serial number.

Get help to fix this fault by requesting a quote

Browse other New Holland codes