3915

New Holland 3915 – ENGINE: Pressure Relief Valve: Averaged rail pressure is outside the expected range with open PRV

Issue description

The averaged rail pressure is not within the expected range, and the Pressure Relief Valve is open. This indicates a potential issue with the Pressure Relief Valve or the system it is part of.

Check the cause

  1. Pressure Relief Valve

  2. the affected circuit

Repair steps

  1. Inspect

    Inspect the Pressure Relief Valve for signs of damage or improper function.

  2. Test

    Test the affected circuit to determine if it is operating as expected.

  3. Replace

    If the Pressure Relief Valve is found to be faulty, replace it with a compatible component.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote