3957
New Holland 3957: Injector 1 And/Or 4 Shorted To Low Source Amber
Issue description
The fault code indicates that Injector 1 and/or Injector 4 is shorted to low source, which may cause improper operation or failure of the affected injector(s). This condition is flagged as amber, indicating a warning level issue.
Check the cause
Injector 1
Injector 4
the affected circuit
Repair steps
Inspect
Visually inspect Injector 1 and Injector 4 for signs of damage, wear, or physical faults.
Test
Test the electrical circuit of Injector 1 and Injector 4 for shorting to low source using a multimeter or diagnostic tool.
Replace
If a short is confirmed, replace the affected injector(s) as needed.
Parts you might need
(0)Get help to fix this fault by requesting a quote