New Holland 3957 – ENGINE: COM1 Output Short to Ground or TWV1 or 3 Output Short to Ground
Issue description
The fault code indicates a short to ground in the COM1 output circuit or in the output circuits of TWV1 or TWV3. This may cause improper operation of the affected circuits or components.
Check the cause
The COM1 output wiring and connections for signs of damage or grounding
The TWV1 and TWV3 output wiring and connections for signs of damage or grounding
The integrity of the wiring harness associated with the affected circuits
Repair steps
Inspect
Inspect the COM1 output wiring and connections for damage, wear, or contact with ground.
Inspect
Inspect the TWV1 and TWV3 output wiring and connections for damage, wear, or contact with ground.
Test
Test the wiring harness for continuity and insulation integrity using a multimeter or appropriate testing equipment.
Parts you might need
(0)Get help to fix this fault by requesting a quote