3974

New Holland 3974: EGR Motor Signal Shorted To Power Or Ground

Issue description

The EGR Motor Signal is experiencing a short to power or ground, which may affect the proper operation of the component identified by this code. This condition is indicated by an amber warning.

Check the cause

  1. EGR Motor Signal wiring

  2. EGR Motor Signal connections

  3. the affected circuit

Repair steps

  1. Inspect

    Inspect the EGR Motor Signal wiring for damage, wear, or exposure to moisture.

  2. Test

    Test the EGR Motor Signal connections for proper continuity and insulation.

  3. Check

    Check the affected circuit for any signs of shorting to power or ground.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes