405-03
New Holland 405-03: Pintle Arm Position Sensor Shorted to High Source
Issue description
The Pintle Arm Position Sensor is experiencing a short to high voltage, which may affect the proper operation of the component identified by this code.
Check the cause
Pintle Arm Position Sensor wiring
Pintle Arm Position Sensor connections
Electrical integrity of the affected circuit
Repair steps
Inspect
Inspect the wiring and connections of the Pintle Arm Position Sensor for damage, wear, or improper routing.
Test
Test the electrical integrity of the Pintle Arm Position Sensor and its associated circuit using a multimeter or diagnostic tool.
Replace
If the sensor or its wiring is found to be faulty, replace the Pintle Arm Position Sensor as needed.
Parts you might need
(0)Get help to fix this fault by requesting a quote