New Holland 4100 – AUX / HYD: Remote No.1 No Control Message Received
Issue description
Fault code 4100 indicates a communication breakdown on the Controller Area Network (CAN) bus. The auxiliary or hydraulic electronic control module responsible for the #1 hydraulic remote valve is not receiving command signals from the armrest controller. Because these electronic instructions are not reaching the valve, the #1 remote becomes inoperative even when the operator moves the control lever or switch.
Applies to these machines
16 machines- T7 Series
- T7000
- T7.200
- T8 Series
- T9 Series
- TG Series
- TG245
- TG255
- TG305
- Genesis Series
- 8670
- 8770
- T4 Series
- T5 Series
- Boomer Series
- TN Series
Check the cause
Check for other fault codes (such as 'U' codes or 4042) which can indicate a wider CAN network problem rather than a single component failure
Inspect battery voltage (must be above 12.6V) and ensure all main chassis and cab ground connections are clean, tight, and free of corrosion
Visually inspect the wiring harness between the armrest controller and the #1 remote valve block for chafing, pinching, corrosion, or loose connectors (especially where the harness passes through the cab floor or flexes)
Perform a CAN Bus Resistance Check (Power Off): Measure resistance between CAN High and CAN Low pins (often yellow and green wires). A healthy bus reads ~60 Ohms. 120 Ohms indicates a missing terminator or open circuit. Significantly lower indicates a short or faulty module
Perform a CAN Bus Voltage Check (Power On): Measure CAN High to ground (expected 2.5 to 3.5 Volts) and CAN Low to ground (expected 1.5 to 2.5 Volts)
Repair steps
Address basic power and ground issues
Correct any low battery voltage issues and clean or tighten any loose or corroded ground connections found during initial checks. Clear the fault codes and retest to see if the code returns.
Repair CAN bus wiring
If resistance or voltage checks indicate an open or short circuit, meticulously trace the harness between the armrest controller and the #1 remote valve. Repair damaged wires using appropriate connectors and heat shrink.
Check terminating resistors
If the CAN bus resistance reading was 120 Ohms, inspect the harness for a missing or damaged terminating resistor plug (or integrated controller terminator) and replace/repair as needed.
Isolate faulty modules
If wiring is intact but the fault persists, unplug modules one by one. If unplugging a specific module causes the CAN bus resistance to return to a normal 60 Ohms, that module is likely the source of the problem.
Replace faulty component
Based on isolation diagnostics, replace either the armrest controller (which may have faulty switches or internal circuit board issues) or the electronic module on the #1 remote valve.
Calibrate the system
After replacing a remote valve or controller, perform a calibration procedure via the tractor's diagnostic display menu (sometimes requiring a special diagnostic tool) to teach the system the electronic limits of the valve spool travel.
Parts you might need
(11)Armrest Control Module
47443335General Armrest Control Module
ECU for Armrest Control Module
48068685ECU for Armrest Control Module
Electronic Armrest with EDC
87399131For T7000 series, alternative to 87631906
Armrest ICP Control panel
84366982For T9 series
- General Armrest part87536543
General Armrest part
Two-Spool Remote Valve Kit
710440016Remote Valve Kit
Remote Control Valve
86403116Remote Control Valve
Remote Control Valve with Mega Flow
86026993Remote Control Valve with Mega Flow
For TN, T4, T5 series (superseded by 48095773)
Hydraulic Remote Valve Connector Segment
48095773For TN, T4, T5 series (supersedes part 5185533)
Rear Remote Hydraulic Valve Kit
MT20116103Rear Remote Hydraulic Valve Kit
Get help to fix this fault by requesting a quote