4105

New Holland 4105 – ARU: Remote No.1 Over Voltage

Issue description

The electronic control module has registered a voltage from the number 1 electro-hydraulic remote (EHR) valve circuit that exceeds the manufacturer's specified maximum limit. This overvoltage condition indicates an electrical fault in the affected circuit or a problem with the power supply, which can disrupt the normal operation of the valve, potentially causing it to become unresponsive or behave erratically.

Applies to these machines

  • T6
  • T7
  • T8
  • T9
  • TM Series
  • Magnum
  • MXM

Check the cause

  1. Verify overall system voltage at the battery and alternator (typically 12.6V off, 13.5-14.5V running) to rule out system-wide voltage spikes caused by a malfunctioning alternator or voltage regulator.

  2. Inspect all main power and ground connections for cleanliness and security.

  3. Inspect the wiring harness and connectors leading to the armrest controller and the number 1 remote valve for chafing, corrosion, pinched wires, or backed-out pins (especially wires moving with the seat/armrest).

  4. Test the control potentiometer in the remote valve control lever by back-probing the signal wire for smooth voltage changes while sweeping the lever, or by measuring resistance.

  5. Inspect and test the remote valve solenoid for visible damage, corrosion, or out-of-range resistance (open or short circuit).

Repair steps

  1. Address system voltage issues

    If diagnostic checks reveal an issue with the tractor's charging system, repair the alternator or voltage regulator and clear all fault codes before proceeding.

  2. Repair wiring and connectors

    If any damaged wiring or faulty connectors are found, repair or replace them. Ensure all connections are clean and secure.

  3. Calibrate the EHR system

    After any repairs to the electronic control system, recalibrate the EHR valves through the tractor's diagnostic menu (H-menu routines). This ensures the controller recognizes the valve's operational range. Failure to calibrate can lead to performance issues even if the electrical fault is resolved.

  4. Replace faulty components

    Replace the control lever potentiometer or remote valve solenoid if they fail diagnostic testing. If the wiring, potentiometer, and solenoid are all confirmed to be good, the issue may lie within the Armrest Controller (ARU) itself (e.g., shorted filter caps), requiring replacement.

Parts you might need

(9)
  • Bosch. Verify with machine serial number.

  • Bosch. Verify with machine serial number.

  • Bosch. Verify with machine serial number.

  • For certain TM and T7000 series tractors. Bosch Mfg number 521 610 025.

  • Highly specific to the armrest version; verification is critical.

  • Highly specific to the armrest version; verification is critical.

  • Highly specific to the armrest version; verification is critical.

  • Control Lever Potentiometer

    21.42292

    Highly specific to the armrest version; verification is critical.

  • Armrest Controller (ARU)

    Part numbers are highly specific to the tractor's configuration and serial number. Replace only after exhausting all other possibilities.

Get help to fix this fault by requesting a quote