New Holland 4106 – ARU: Remote No.1 Spool Movement Too Low
Issue description
The control module has detected that the spool for the number one electro-hydraulic remote (EHR) valve is not moving as commanded, or its position is lower than expected. This electronic fault occurs when feedback from the spool position sensor does not match the position instructed by the operator's controls. This condition indicates a problem with the components monitoring or controlling the valve spool and may result in improper function of connected equipment.
Applies to these machines
8 machines- T6 Series
- T6.120
- T6.180
- T7 Series
- T7.170
- T7.260
- T6000
- T7000
Check the cause
Ensure the tractor's battery is fully charged (above 12.6V) and that all ground connections to the chassis and controllers are clean and tight, as low voltage can trigger erroneous codes
Check that the hydraulic fluid level is correct and that the fluid is clean and of the proper specification (e.g., Ambra Multi G 134 or NH 410 B)
Inspect the No. 1 remote valve block and its wiring harness for visible damage, corrosion on connectors, or hydraulic leaks
If equipped, operate the valve using the manual override to determine if the spool is mechanically stuck or if the issue is strictly electrical
Inspect the spool position sensor wiring and connector for damage, chafing, or loose pins
Test the sensor for correct voltage supply and check the signal wire for changing voltage as the remote lever is operated
Observe general hydraulic functions for sluggish or jerky operation, which could indicate a failing pump, clogged filter, or faulty compensator valve
Repair steps
Address basic faults
Rectify any discovered issues with low/contaminated hydraulic fluid, low battery voltage, or damaged wiring. Clear the fault codes and re-test operation.
Calibrate the EHR Valve
If no physical faults are found, attempt a recalibration of the EHR valve via the tractor's diagnostic menu ('H' routines or IntelliView monitor) to teach the controller the end-points of the spool's travel.
Replace spool position sensor
If calibration fails or diagnostics point to the sensor, clean the area around the No. 1 remote valve, disconnect the electrical connector, and unscrew the sensor. Install the new sensor ensuring seals/O-rings are seated correctly, then reconnect.
Perform post-replacement calibration
After replacing the spool position sensor, perform the EHR valve calibration routine again so the controller recognizes the new sensor's output.
Replace remote valve assembly
If the fault persists after sensor replacement and successful calibration, the issue likely lies within the valve body (mechanically stuck spool/internal leak) or the electronic driver. Repair or replace the entire remote valve section.
Parts you might need
(2)Supersedes 84385135, 87312136, 47128303, 5184312. Fits various T6, T7, T6000, T7000 series.
Two-Spool Remote Control Valve Assembly
710440016Example part number only. It is crucial to verify the correct part number using the tractor's serial number.
Get help to fix this fault by requesting a quote