New Holland 4111 – ARU: Remote No.1 potentiometer faulty

Issue description

The control module has detected an issue with the electrical signals from the potentiometer connected to the first remote hydraulic valve lever. The potentiometer translates the physical position of the control lever into a voltage signal. A fault indicates that this signal is out of the expected range, erratic, or absent, which can lead to the remote valve being unresponsive or behaving unpredictably.

Applies to these machines

  • T6010
  • T6020
  • T6030
  • T6040
  • T6050
  • T6060
  • T6070
  • T7030
  • T7040
  • T7050
  • T7060
  • TM115
  • TM120
  • TM125
  • TM130
  • TM135
  • TM140
  • TM150
  • TM155
  • TM165
  • TM175
  • TM190
  • TS90
  • TS100
  • TS110
  • TS115
  • TS100A
  • TS110A
  • TS115A
  • TS135A
  • TL70
  • TL80
  • TL90
  • TL100
  • T4020
  • T4030
  • T4040
  • T4050

Check the cause

  1. Check the wiring and connectors between the remote lever in the armrest and the control module for any visible damage, corrosion, or loose connections

  2. Identify the faulty lever by neutralizing the levers on startup; moving the lever for remote #1 may affect or clear the warning light, confirming it as the source

  3. Check the diagnostic display for other active fault codes to rule out systemic issues like low battery voltage or a bad ground connection

Repair steps

  1. Initiate calibration mode

    With the tractor engine off, turn the ignition key to the 'ON' position. Press and hold the timer switch located on the remote #1 valve until the timer light illuminates and the instrument panel displays a '1'.

  2. Perform lever calibration

    Set the flow control knob for remote #1 to its maximum position. Move the control lever to its full 'raise' or 'extend' position and hold it until the display changes (e.g., to a '3'). Then move the lever to the full 'lower' or 'retract' position and hold it. If the fault was due to a loss of synchronization, the code should clear.

  3. Access the armrest internals

    If calibration fails to resolve the fault, the potentiometer is likely faulty. Remove the armrest covers and panels to access the remote lever assemblies.

  4. Remove the faulty potentiometer

    Locate the potentiometer attached to the base of the control lever for remote #1. Disconnect its electrical connector and unfasten any screws or clips holding it in place.

  5. Install the new potentiometer

    Mount the new potentiometer, ensuring it is correctly oriented and mechanically engaged with the lever mechanism. Reconnect the electrical connector.

  6. Reassemble and recalibrate

    Reassemble the armrest console. Perform the re-calibration procedure again to synchronize the new component with the control system.

Parts you might need

(7)
  • 4000 Ohm, for electronic remote valve levers in the armrest. Verify fitment by serial number.

  • Potentiometer

    82021036

    4000 Ohm, for electronic remote valve levers in the armrest. Verify fitment by serial number.

  • 4000 Ohm, for electronic remote valve levers in the armrest. Verify fitment by serial number.

  • 4000 Ohm, for electronic remote valve levers in the armrest. Verify fitment by serial number.

  • EHR Flow Control Knob Potentiometer

    87663294

    Fits New Holland T Series tractors

  • Listed for T8030 and similar models

  • 3/8-32 Retaining Nut

    A39888

    Hardware for retaining potentiometer