New Holland 4111 – ARU: Remote No.1 potentiometer faulty
Issue description
The control module has detected an issue with the electrical signals from the potentiometer connected to the first remote hydraulic valve lever. The potentiometer translates the physical position of the control lever into a voltage signal. A fault indicates that this signal is out of the expected range, erratic, or absent, which can lead to the remote valve being unresponsive or behaving unpredictably.
Applies to these machines
38 machines- T6010
- T6020
- T6030
- T6040
- T6050
- T6060
- T6070
- T7030
- T7040
- T7050
- T7060
- TM115
- TM120
- TM125
- TM130
- TM135
- TM140
- TM150
- TM155
- TM165
- TM175
- TM190
- TS90
- TS100
- TS110
- TS115
- TS100A
- TS110A
- TS115A
- TS135A
- TL70
- TL80
- TL90
- TL100
- T4020
- T4030
- T4040
- T4050
Check the cause
Check the wiring and connectors between the remote lever in the armrest and the control module for any visible damage, corrosion, or loose connections
Identify the faulty lever by neutralizing the levers on startup; moving the lever for remote #1 may affect or clear the warning light, confirming it as the source
Check the diagnostic display for other active fault codes to rule out systemic issues like low battery voltage or a bad ground connection
Repair steps
Initiate calibration mode
With the tractor engine off, turn the ignition key to the 'ON' position. Press and hold the timer switch located on the remote #1 valve until the timer light illuminates and the instrument panel displays a '1'.
Perform lever calibration
Set the flow control knob for remote #1 to its maximum position. Move the control lever to its full 'raise' or 'extend' position and hold it until the display changes (e.g., to a '3'). Then move the lever to the full 'lower' or 'retract' position and hold it. If the fault was due to a loss of synchronization, the code should clear.
Access the armrest internals
If calibration fails to resolve the fault, the potentiometer is likely faulty. Remove the armrest covers and panels to access the remote lever assemblies.
Remove the faulty potentiometer
Locate the potentiometer attached to the base of the control lever for remote #1. Disconnect its electrical connector and unfasten any screws or clips holding it in place.
Install the new potentiometer
Mount the new potentiometer, ensuring it is correctly oriented and mechanically engaged with the lever mechanism. Reconnect the electrical connector.
Reassemble and recalibrate
Reassemble the armrest console. Perform the re-calibration procedure again to synchronize the new component with the control system.
Parts you might need
(7)- Potentiometer87605247
4000 Ohm, for electronic remote valve levers in the armrest. Verify fitment by serial number.
Potentiometer
820210364000 Ohm, for electronic remote valve levers in the armrest. Verify fitment by serial number.
- Potentiometer87605245
4000 Ohm, for electronic remote valve levers in the armrest. Verify fitment by serial number.
- Potentiometer82021035
4000 Ohm, for electronic remote valve levers in the armrest. Verify fitment by serial number.
EHR Flow Control Knob Potentiometer
87663294Fits New Holland T Series tractors
Listed for T8030 and similar models
3/8-32 Retaining Nut
A39888Hardware for retaining potentiometer
Get help to fix this fault by requesting a quote