4117

New Holland 4117 – ARU: REMOTE NO.2 SWITCHED TO FAILSAFE

Issue description

The electronic control system for the number 2 rear electro-hydraulic remote (EHR) valve has detected a critical fault and entered a limited, safe-operating mode. This failsafe mode restricts or disables the valve's operation to prevent unpredictable behavior or further damage to the hydraulic system. This code is typically a general indicator triggered by underlying electrical, mechanical, or hydraulic issues, and is often accompanied by more specific fault codes.

Applies to these machines

  • T7.220
  • T7.235
  • T7.250
  • T7.260
  • T7.270
  • T6030

Check the cause

  1. Check for other active fault codes related to Remote No.2 (e.g., 4118/4119 for voltage, 4120/4121 for spool movement, 4124/4125 for electronic failures, 4114 for CAN bus)

  2. Inspect the wiring harness and connectors leading to the number 2 remote valve assembly for damage, corrosion, loose pins, or moisture intrusion

  3. Check hydraulic fluid level and condition, ensuring it is not contaminated

  4. Listen for unusual noises from the hydraulic system (whining or squealing) indicating pressure issues or a struggling pump

  5. Test the in-cab operator controls (switch or lever in the armrest) for proper function

Repair steps

  1. Address specific fault codes

    Diagnose and repair any accompanying specific fault codes first. For example, troubleshoot the power supply for under-voltage code 4118, or replace electronic components for potentiometer code 4125.

  2. Repair wiring and connectors

    If electrical inspection revealed damage, repair the affected wires or replace the harness section. Clean corroded connectors and ensure secure connections.

  3. Service the remote valve

    If spool sticking is suspected (indicated by codes 4120/4121), remove, disassemble, and clean the valve. Inspect for worn or damaged O-rings and seals, and replace as necessary.

  4. Calibrate the remote valve

    After any repair or replacement, perform a valve calibration through the tractor's diagnostic 'H' menu. Ensure hydraulic oil is at the specified operating temperature. If calibration fails, re-check for mechanical or electrical faults.

  5. Replace valve components

    If diagnosis points to a failed internal component (solenoid or potentiometer), replace the entire electro-hydraulic valve slice for the #2 remote.

Parts you might need

(15)
  • Rear Remote Valve

    719195010

    Verify fitment by serial number

  • Rear Remote Hydraulic Valve Kit

    MT20116103

    Verify fitment by serial number

  • Applicable to models like T6030.

  • Control Valve Slice

    87546170

    Applicable to models like T6030.

  • Control Valve Slice (Remanufactured)

    84175671R

    Remanufactured version.

  • O-rings and seals

    Required when replacing the valve slice to ensure proper function

  • Replaces older numbers: 82012603, 82017351, 82021036, 82033385, 87559692, 82010303. Fitment: T6, T7, TM, TS, TN series.

  • Alternative OEM Part. Replaces 9607595, 9821734, 84428435, 83983693.

  • Example fitment for TG285. Often manufactured by Rexroth or Bosch for CNH.

  • O-Ring Seal, 0.103'' Thk x 0.799'' ID

  • Fits various T6000 series. Verify with dealer using serial number.

  • Rear Remote Hydraulic Valve Section

    47595556

    Listed for T9.615. Verify with dealer using serial number.

  • Rear Remote Hydraulic Valve Section

    87496186C

    Verify fitment by serial number.

  • Rear Remote Hydraulic Valve Section

    86026993

    Verify fitment by serial number.

  • Rear Remote Hydraulic Valve Kit

    718334006

    Kit for adding/replacing complete remote valve spool.

Get help to fix this fault by requesting a quote

Browse other New Holland codes