New Holland 4118 – ARU: Remote No.2 Under Voltage
Issue description
The control system has detected an under-voltage condition in the circuit for the second rear electro-hydraulic remote valve. This below-minimum voltage prevents the proper activation and function of the hydraulic remote, potentially leaving it inoperable. This indicates an electrical fault rather than a mechanical or hydraulic failure.
Applies to these machines
8 machines- T5 Series
- T6 Series
- T7 Series
- T7 AutoCommand
- T7 Power Command
- T7 Range Command
- TM Series
- TSA Series
Check the cause
Check overall system voltage to ensure the battery is fully charged and the alternator is functioning correctly, as a battery voltage below 12.1V can be a source of ghost codes
Inspect all relevant fuses for the hydraulic and armrest control systems
Inspect the main ground strap to the chassis to ensure it is clean, tight, and free of corrosion
Visually inspect the wiring harness leading to the No. 2 remote valve solenoid for chafing, cuts, or heat damage. Pay close attention to the connectors at both the solenoid and the controller for loose pins, corrosion, or moisture intrusion, as well as wiring and connectors under the cab or near the armrest
Determine if the code is active (present now) or stored (occurred in the past) using the tractor's diagnostic display or an external diagnostic tool to identify intermittent faults
Repair steps
Prepare machine for service
Ensure the tractor is on level ground, parking brake engaged, and engine off. Disconnect the battery to prevent electrical shorts and relieve any residual pressure in the hydraulic system.
Locate the No. 2 remote valve
Identify the No. 2 rear electro-hydraulic remote valve solenoids mounted on the hydraulic valve block at the rear of the tractor (typically the second from one side).
Test the solenoid
Disconnect the wiring harness from the solenoid. Measure resistance across the two pins of the coil using a multimeter. Compare to a known good solenoid; a reading of 'OL' indicates an open circuit, while near zero indicates a short circuit.
Test the wiring harness
With the solenoid and the controller end disconnected (if accessible), perform a continuity test on each wire in the harness for the No. 2 remote to check for breaks. Check for shorts to ground (wire to chassis) and shorts between wires.
Perform a voltage test
Reconnect the battery and harness. Carefully back-probe the connector at the solenoid while an assistant activates the No. 2 remote from the cab. A reading significantly below system voltage (e.g., below 12V with the engine running) confirms the under-voltage condition at the component.
Replace faulty components
Replace the solenoid if it tests faulty, or repair/replace damaged wiring. If both are good, the Armrest Control Unit (ARU) may be faulty and require advanced diagnostics before replacement.
Parts you might need
(12)- Solenoid Valve Assembly84273815
- Solenoid Valve Assembly87472229
- Solenoid Valve Assembly87723774
- Electro-Valve87395799
Component of remote
- Remote Valve Assembly87526168
Complete assembly
Aftermarket Solenoid Coil
QTP-44308Fits various T5, T6, T7, TM, TSA models
Replaces 84356319 for some T7 models
Replaced by 48068689 for some T7 models
Example for T6000 series. Also fits some Case IH Maxxum models.
Rear Remote Hydraulic Valve Kit
MT20116103Example kit
- Remote Valve Harness87351208
Example for T8000 series
- Remote Valve Harness87748970
Alternative example for T8000 series
Get help to fix this fault by requesting a quote