4119

New Holland 4119 – ARU / TCU: Remote Control Valve No. 2 Voltage Exceeded

Issue description

The control system has detected an abnormally high voltage signal related to the second electro-hydraulic remote valve. This suggests an electrical malfunction rather than a purely mechanical or hydraulic issue. The system continuously monitors the voltage in the circuits of the remote valves, and this code is triggered when the reading for valve #2 surpasses the predefined acceptable range.

Applies to these machines

  • T4
  • T5
  • T7
  • T8
  • T9
  • Genesis

Check the cause

  1. Verify battery and system voltage (ensure battery is around 12.6V with engine off and charging system functions correctly, as low voltage can trigger erroneous codes)

  2. Check the diagnostic display for any other active fault codes that could provide additional clues

  3. Inspect the wiring harness and connectors leading to the #2 remote valve solenoid and armrest controller for chafed wires, pinched wires, corrosion, or a short circuit to a power source

  4. Inspect the remote levers and switches in the armrest for erratic behavior

  5. Check the condition of the solenoid on the #2 remote valve

Repair steps

  1. Test electrical voltage

    Using a multimeter, check the voltage at the connector for the #2 remote valve solenoid. Excessively high voltage points to a short circuit in the wiring harness. Normal voltage points to an issue with the solenoid or armrest controller.

  2. Swap solenoids to isolate fault

    Swap the solenoid from valve #2 with one from a functioning remote (e.g., valve #3). If the fault code moves to the other remote, the solenoid is faulty. If it remains on valve #2, the problem is in the wiring or armrest controller.

  3. Diagnose and recalibrate armrest controller

    Recalibrate the remote levers through the tractor's display. If calibration fails or the problem persists, replace the faulty potentiometer, switch, or the entire armrest controller assembly.

  4. Replace faulty solenoid

    If the component swapping test determined the solenoid is faulty, replace the #2 remote valve solenoid.

  5. Clear codes and recalibrate

    After completing repairs, clear the fault codes from the system and perform a final calibration of the electronic remote valves.

Parts you might need