Skip to main content
4119

New Holland 4119 – ARU: Remote No.2 Over Voltage

Issue description

The Armrest Control Unit (ARU) has detected an overvoltage condition on the circuit for the number two electro-hydraulic remote (EHR) valve. This indicates the electrical circuit is receiving voltage above the specified limit, which may be caused by a charging system malfunction, a short circuit to a power source, or an internal failure within the control module or the component itself.

Applies to these machines

  • T6
  • T7
  • T8
  • T9
  • TG Series
  • MX Series

Check the cause

  1. Verify overall system voltage at the battery and alternator (should be approximately 12V with key on, and 13.5V-14.5V running; readings over 15V indicate a charging system issue)

  2. Inspect the wiring harness and connectors leading to the number two remote valve and the armrest controller for damage, corrosion, or pinched wires causing a short to power

  3. Check for other fault codes, particularly those related to system voltage or other remote valves, which would indicate a system-wide overvoltage issue

  4. Isolate the component by swapping the electrical connector from remote valve #2 with an adjacent functioning remote valve (e.g., #3) to see if the fault follows the connector or stays with the valve

Repair steps

  1. Test remote valve solenoid

    Disconnect the electrical connector from the solenoid for remote valve #2. Measure resistance across the two pins (infinite indicates an open circuit, near zero indicates a short). Test for voltage at the harness connector pins with the key on.

  2. Test armrest controller and wiring

    If the solenoid tests good, access the armrest controller. With the key on, back-probe the connector pin corresponding to the output for remote valve #2. If voltage is abnormally high at the source, the controller may be faulty. Use a service manual or wiring diagram to identify the correct pins for testing, and access diagnostic menus if available to view live data from the remote levers and potentiometers.

  3. Replace faulty components

    Replace the remote valve solenoid, armrest controller, or repair the damaged section of the wiring harness based on the testing results.

  4. Calibrate and verify

    If a remote valve or armrest controller was replaced, perform a calibration procedure through the tractor's diagnostic interface. Clear all fault codes and operate the #2 remote valve to ensure the fault does not return.

Parts you might need

(14)
  • Two-Spool Remote Valve Kit

    710440016

    OEM part

  • Valve, Remote CO

    86403116

    OEM part

  • Remote Control Valve w/ Mega Flow

    86026993

    OEM part

  • Rear Remote Hydraulic Valve Kit

    MT20116103

    OEM part

  • Reman Armrest Controller

    84165726R

    OEM part

  • Armrest Controller

    87399131

    OEM part for T7000 series

  • Electronic Control Unit for Armrest Control Module

    48068685

    OEM part

  • OEM part

  • Armrest Controller

    84366982

    OEM part for T9 series

  • Common on T6, T7, and T4 series

  • Common on T5, T6, and TL series

  • Replaces older numbers 9607595, 84428435, 83980855; common on TN, TS, 40, 70, and Ford series

  • Main Remote Valve Section (Center Slice)

    47595556

    Fits T8 series and Case IH Magnum

  • Main Remote Valve Section (Center Slice)

    87496186

    Fits T8 series and Case IH Magnum

Get help to fix this fault by requesting a quote

Browse other New Holland codes