New Holland 4125 – EHR: Remote No. 2 Potentiometer Faulty
Issue description
The control module has detected a problem with the internal position sensor (potentiometer or position transducer) of the second rear hydraulic remote valve. This sensor is responsible for reporting the exact position of the valve's spool to the control system. A faulty sensor means the control module cannot accurately determine the position of the remote valve, which can lead to improper or unpredictable operation of the hydraulic implement connected to that circuit.
Applies to these machines
12 machines- T7.170
- T7.185
- T7.200
- T7.210
- T7.220
- T7.235
- T7.250
- T7.260
- T7.270
- T6 Series
- T8 Series
- T9 Series
Check the cause
Visually inspect the wiring harness leading to the armrest controls and the number 2 remote valve lever for damage, chafing, or loose connections
Check the tractor's diagnostic menu for other active fault codes (multiple potentiometer or communication codes could indicate a systemic issue like low battery voltage or a poor ground connection)
Disconnect the tractor's battery before accessing electrical components
Remove the covers from the armrest to access the wiring for the number 2 remote control lever
Identify the three terminals on the potentiometer: two outer terminals for total resistance and a central wiper terminal
Measure total resistance by setting a multimeter to Ohms (Ω) and measuring between the two outer terminals (should be stable and match the component's specification, e.g., 5kΩ or 10kΩ)
Test the wiper by connecting one probe to the center (wiper) terminal and the other to one of the outer terminals, then slowly moving the control lever through its full range of motion (resistance should change smoothly without sudden jumps, dropouts to zero, or open circuits)
Repair steps
Disconnect power
Ensure the tractor's battery is disconnected before accessing electrical components.
Access the armrest controls
Remove the necessary panels and covers to gain access to the remote lever assembly within the armrest console.
Remove the faulty lever
Label and disconnect the electrical connector from the number 2 remote lever. Unbolt the lever assembly from the armrest console.
Install the new lever
Mount the new remote lever assembly into the armrest, ensuring it is securely fastened. Reconnect the electrical connector.
Reassemble and power on
Reinstall the armrest covers and reconnect the battery.
Perform calibration
Calibrate the new remote lever through the tractor's display service or diagnostic menu so the control module can learn the new potentiometer's minimum, maximum, and neutral positions.
Parts you might need
(9)- Multi-function joystick lever47826727
For T7 series tractors
Multi-function joystick lever
84208937For T7 series tractors
- Multi-function handle47826726
For SideWinder II armrests
Armrest Control Module
47443335Verify fitment by serial number
Electro-Hydraulic Remote Control Lever / Joystick
Generic replacement assembly if specific OEM numbers do not match
EHR Flow Control Knob Potentiometer
87663294Fits various New Holland "T Series" tractors
Complete Remote Control Valve section
86026993For older Mega Flow systems like the 8670A-8970A
Remote Valve section
5146538Fits T6020 and similar models
OEM CNH part. The position sensor is not sold separately. Verify fitment with tractor serial number before ordering.
Get help to fix this fault by requesting a quote