New Holland 4127: Rear remote control valve No. 2 - spool is not in the neutral position when the ignition is turned on
Issue description
The rear remote control valve No. 2 spool is not in the neutral position when the ignition is turned on, which may affect the proper operation of the connected system.
Check the cause
The position of the rear remote control valve No. 2 spool when the ignition is on
The mechanical linkage or actuation mechanism for the rear remote control valve No. 2 spool
The electrical signal or input to the rear remote control valve No. 2 spool
Repair steps
Verify the position of the rear remote control valve No. 2 spool
Check that the spool is in the neutral position when the ignition is on.
Inspect the mechanical linkage
Check for any binding, damage, or misalignment in the mechanical linkage connected to the rear remote control valve No. 2 spool.
Check the electrical input
Ensure that the electrical signal or input to the rear remote control valve No. 2 spool is functioning correctly.
Parts you might need
(0)Get help to fix this fault by requesting a quote