New Holland 4171 – EHR: EHR Control Lever 1 Open Circuit
Issue description
The Electronic Hitch Control (EHR) module has detected an open circuit in the electrical wiring or components associated with the No. 1 EHR control lever. This indicates a break or disconnection in the electrical path, preventing current from flowing and stopping the control module from receiving a signal from the lever.
Applies to these machines
9 machines- T9.390
- T9.615
- T6030
- T6050
- T6070
- T6080
- TM120
- TM190
- MXM190
Check the cause
Check battery voltage and ensure all main chassis and cab ground straps are clean and secure, as low voltage can trigger erroneous codes
Visually inspect the wiring harness leading to and from the No. 1 EHR control lever on the armrest for chafing, pinching, corrosion, or disconnected plugs
Swap the electrical connectors between the No. 1 and No. 2 EHR control levers (if equipped). If the fault changes to 4174, the lever is faulty; if 4171 remains, the wiring harness is the issue
Attempt a lever calibration procedure, as a loss of calibration can sometimes trigger this fault code
Repair steps
Isolate the Fault
Perform the diagnostic checks listed above to determine if the fault lies with the control lever itself or the wiring harness.
Address Wiring Issues
If a wiring issue is identified (chafing, broken wire, corroded connector), repair the specific section of the harness. Ensure all connections are clean, secure, and protected from future damage.
Replace the Control Lever
If the control lever is determined to be faulty, it will need to be replaced. On many models, the EHR levers are part of a larger armrest control assembly. Accessing the lever may require disassembly of the armrest.
Clear Fault Codes
After the repair is complete, clear the stored fault codes using the tractor's diagnostic menu or a service tool.
Safety First (Calibration)
Park the tractor on a level surface, apply the parking brake, and ensure no implements are connected to the rear remotes.
Enter Diagnostic Mode
Use the instrument cluster keys to navigate to the diagnostic menu (often designated as 'H' routines) and select mode H1. The display should show 'CAL'.
Initiate Calibration for Lever 1
Depress the program switch for lever No. 1 three times. The display will show '1'.
Calibrate Lever Positions
The system will prompt you to move the lever to specific positions. Follow the on-screen prompts, which will typically guide you through moving the lever to neutral, full raise, full flow lower, and float positions, waiting for confirmation at each step.
Store Calibration
Once the sequence is complete for the lever, turn the key to the 'OFF' position to save the calibration values.
Parts you might need
(7)Electronic Armrest with Lift/EHR Controls
87648539Fitment: T6000 Series (T6030, T6050, T6070, T6080)
- EHR Control Lever, 3 Lever84172184
Fitment: T9 Series (e.g., T9.505)
Fitment varies, verify with dealer
Electro-Hydraulic Remote Lever (includes wire harness)
48002177Fitment varies, verify with dealer
EHR Control Valve Wire Harness
51618177Fitment varies, verify with dealer
EHR Control Valve Wire Harness
84151662Fitment: T9, Quadtrac, and Rowtrac models
EHR Control Valve Wire Harness
47901610Fitment varies, verify with dealer