Skip to main content
4171

New Holland 4171 – EHR: EHR Control Lever 1 Open Circuit

Issue description

The Electronic Hitch Control (EHR) module has detected an open circuit in the electrical wiring or components associated with the No. 1 EHR control lever. This indicates a break or disconnection in the electrical path, preventing current from flowing and stopping the control module from receiving a signal from the lever.

Applies to these machines

  • T9.390
  • T9.615
  • T6030
  • T6050
  • T6070
  • T6080
  • TM120
  • TM190
  • MXM190

Check the cause

  1. Check battery voltage and ensure all main chassis and cab ground straps are clean and secure, as low voltage can trigger erroneous codes

  2. Visually inspect the wiring harness leading to and from the No. 1 EHR control lever on the armrest for chafing, pinching, corrosion, or disconnected plugs

  3. Swap the electrical connectors between the No. 1 and No. 2 EHR control levers (if equipped). If the fault changes to 4174, the lever is faulty; if 4171 remains, the wiring harness is the issue

  4. Attempt a lever calibration procedure, as a loss of calibration can sometimes trigger this fault code

Repair steps

  1. Isolate the Fault

    Perform the diagnostic checks listed above to determine if the fault lies with the control lever itself or the wiring harness.

  2. Address Wiring Issues

    If a wiring issue is identified (chafing, broken wire, corroded connector), repair the specific section of the harness. Ensure all connections are clean, secure, and protected from future damage.

  3. Replace the Control Lever

    If the control lever is determined to be faulty, it will need to be replaced. On many models, the EHR levers are part of a larger armrest control assembly. Accessing the lever may require disassembly of the armrest.

  4. Clear Fault Codes

    After the repair is complete, clear the stored fault codes using the tractor's diagnostic menu or a service tool.

  5. Safety First (Calibration)

    Park the tractor on a level surface, apply the parking brake, and ensure no implements are connected to the rear remotes.

  6. Enter Diagnostic Mode

    Use the instrument cluster keys to navigate to the diagnostic menu (often designated as 'H' routines) and select mode H1. The display should show 'CAL'.

  7. Initiate Calibration for Lever 1

    Depress the program switch for lever No. 1 three times. The display will show '1'.

  8. Calibrate Lever Positions

    The system will prompt you to move the lever to specific positions. Follow the on-screen prompts, which will typically guide you through moving the lever to neutral, full raise, full flow lower, and float positions, waiting for confirmation at each step.

  9. Store Calibration

    Once the sequence is complete for the lever, turn the key to the 'OFF' position to save the calibration values.

Parts you might need

(7)
  • Electronic Armrest with Lift/EHR Controls

    87648539

    Fitment: T6000 Series (T6030, T6050, T6070, T6080)

  • Fitment: T9 Series (e.g., T9.505)

  • Fitment varies, verify with dealer

  • Electro-Hydraulic Remote Lever (includes wire harness)

    48002177

    Fitment varies, verify with dealer

  • EHR Control Valve Wire Harness

    51618177

    Fitment varies, verify with dealer

  • EHR Control Valve Wire Harness

    84151662

    Fitment: T9, Quadtrac, and Rowtrac models

  • EHR Control Valve Wire Harness

    47901610

    Fitment varies, verify with dealer

Get help to fix this fault by requesting a quote