New Holland 4172 – EHR: Rear EHR Control No.1 Short Circuit
Issue description
The EHR control module (DU Module) has detected a short circuit in the electrical circuit for the No. 1 rear Electronic Hydraulic Remote (EHR) valve. This indicates an unintended path of low resistance to ground or between wires, causing excessive current flow. This electrical issue will likely disable the function of the corresponding rear remote valve.
Applies to these machines
10 machines- T4
- T5
- T6
- T7
- T8
- T6000 Series
- T6000 Delta
- T6000 Plus
- TM Series
- TN-DA Series
Check the cause
Visually inspect the wiring harness leading to the No. 1 rear EHR valve for chafed or melted insulation, pinched wires, corrosion in the connectors, or rubbing against the tractor frame or other components.
Disconnect the electrical connector at the No. 1 EHR valve and inspect the terminals for corrosion, moisture, or damage. Ensure the terminals are clean and making a secure connection.
Use the tractor's 'H' menu diagnostics (if equipped) to view stored fault codes and perform voltmeter diagnostics to check circuit integrity.
With the key off and valve disconnected, use a multimeter to check resistance to ground (a very low reading indicates a short to ground).
With the key off and valve disconnected, use a multimeter to check resistance between wires in the harness connector (a low reading indicates a short between wires).
Repair steps
Isolate the fault
Disconnect the wiring harness from the No. 1 rear EHR valve solenoid.
Clear fault codes
Clear the fault code 4172 from the control module.
Check for code return
Turn the key on and attempt to operate the remote. If the fault code does not return, the short circuit is likely within the EHR valve solenoid itself. If the fault code returns immediately with the valve disconnected, the short is in the wiring harness between the control module and the valve.
Repair wiring harness
If the fault is isolated to the wiring harness, carefully trace the wires from the EHR valve connector back to the control module. Repair or replace any damaged sections of the wiring, ensuring all repairs are sealed against moisture and vibration.
Replace EHR valve or solenoid
If the fault was isolated to the valve itself (code did not return when disconnected), replace the solenoid or the entire valve assembly.
Calibrate the new valve
After replacing an EHR valve or control module, perform a calibration procedure through the tractor's diagnostic 'H' menu to teach the control module the operational range of the new valve. Failure to calibrate may result in a 'Not Calibrated' fault code (e.g., 4170).
Parts you might need
(8)Rear Remote Hydraulic Valve #1 Position Complete
719936046Example OEM part number; verify fitment by serial number
Remote Control Valve w/ Mega Flow
86026993Verify fitment by serial number
Rear Remote Hydraulic Valve Kit
MT20116103Verify fitment by serial number
Remote Valve Kit
731200551Verify fitment by serial number
Alternative/Superseded: 82024122. Fitment: T7000 Series, TM175, TM190
Electronic Armrest Lift & EHR Control Assembly
87648539Fitment: T6000 Series (T6030, T6050, T6070, T6080)
- EHR Control Panel82012643
EHR Control Valve Wire Harness
84158327