New Holland 4173 – TCU or ARU: Rear Control Unit EHR No. 2 - Not Calibrated

Issue description

The electro-hydraulic rear remote valve number 2 has not been calibrated. The controller has lost or lacks the necessary parameters to operate the valve correctly, which may affect the proper operation of the associated hydraulic system. The system requires calibration to learn the valve's operational limits. While uncalibrated valves may still operate, their control and response will be unpredictable, and it is not recommended to use an implement until calibration is restored.

Applies to these machines

  • T7.170
  • T7.200
  • T7.220
  • T7.235
  • T7.250
  • T7.260
  • T7.270
  • T8.275
  • T8.300
  • T8.330
  • T8.360
  • T8.390
  • T9 Series
  • TM Series (TM115-TM165)
  • MXM Series
  • T6030
  • T6050
  • T6070
  • T6080

Check the cause

  1. Inspect the wiring harness and connectors leading to the No. 2 rear EHR valve for visible damage, corrosion, or loose connections

  2. Check hydraulic fluid level and ensure it is warmed up to the required temperature (e.g., 50°C or 122°F) for calibration

  3. Verify system voltage and check for any other fault codes related to low or high voltage, which can affect electronic control modules

  4. Ensure the operator is seated in the seat, as the seat switch must be activated for certain functions and calibrations

Repair steps

  1. Enter Calibration Mode

    Access the calibration mode through the tractor's instrument cluster display (often the 'H' menu) or by using the New Holland Electronic Service Tool (EST).

  2. Select Valve

    Navigate through the menu to select the rear remote valve that needs calibration (EHR No. 2).

  3. Initiate Calibration

    Follow the on-screen prompts to start the process. This typically involves moving the corresponding control lever to its full extent and returning it to neutral.

  4. Follow On-Screen Instructions

    Complete any additional prompted steps on the instrument panel, such as setting the flow control to maximum.

  5. Save and Exit

    Once calibration is complete, save the settings and exit calibration mode.

  6. Diagnose Hardware

    If calibration fails repeatedly, use the Electronic Service Tool to diagnose potential internal valve faults or issues with the control lever/potentiometer.

Parts you might need

(5)
  • For some T7000, TM175, TM190 series

  • Electronic Armrest Lift/EHR Control

    87648539

    For some T6000 series

  • Remanufactured option for the electronic lever control

  • Control Unit

    SBA385870641

    General control unit, verification required

  • Control Unit

    SBA385870612

    General control unit, verification required

Get help to fix this fault by requesting a quote

Browse other New Holland codes