New Holland 4179 – EHR / ARU: EHR Control No. 3 Short Circuit
Issue description
The electronic control system has detected a short circuit in the electrical circuit for the third Electronic Hitch Control (EHR) rear remote valve. A short circuit is a low-resistance connection causing excessive current flow, which will likely disable the function of the number 3 rear remote valve.
Applies to these machines
10 machines- T4
- T5
- T6030
- T6050
- T6070
- T6080
- T7.170
- T7.290
- T8.380
- T9 Series
Check the cause
Check the tractor's diagnostic menu for other active fault codes, especially those related to voltage or communication, which could indicate a widespread electrical issue
Inspect the battery and charging system (ensure battery is above 12.6V, alternator is functioning, and chassis grounds/terminals are clean and tight)
Visually inspect the wiring harness leading to the No. 3 rear remote valve for chafing, pinching, or rodent damage, especially around moving parts
Disconnect and inspect the electrical connectors for the No. 3 EHR valve (typically at the rear valve block) and the main armrest control unit for corrosion, moisture ingress, or bent pins
Perform a circuit swap test: swap the electrical connectors between the No. 3 valve and an adjacent functioning valve (e.g., No. 2 or No. 4) to isolate the fault to either the wiring/module or the valve solenoid itself
Repair steps
Repair or replace wiring harness
If the swap test causes the fault code to change to the other remote (e.g., 4175), the issue is in the wiring harness or control module. Repair the damaged section of the wire or replace the entire harness, ensuring all repairs are sealed against moisture.
Clean or replace connectors
If connectors are corroded, clean them using an appropriate electrical contact cleaner. If pins are damaged, replace the connector or individual pins.
Replace EHR valve solenoid
If the fault code 4179 remains active on remote No. 3 during the swap test, the issue is likely with the No. 3 valve's solenoid or internal components. Replace the valve section or solenoid assembly.
Replace EHR control module
If the wiring and valve solenoids test good but the fault persists, replace the EHR or Armrest Control Unit. A calibration of the new component will be required after installation.
Parts you might need
(9)EHR Control Valve Wire Harness
47901610EHR Control Valve Wire Harness
84151662- EHR Control Valve Wire Harness87748970
For T8030 models
- EHR Control Unit/Module82012644
- EHR Control Unit/Module82024840
- EHR Control Unit/Module87397177
EHR Control Unit/Module
87530854EHR Control Valve Assembly
84230143Complete control valve assembly for T7.170
- Remanufactured EH Lever Control47372893R
Get help to fix this fault by requesting a quote