New Holland 4180 – EHR: Rear Remote No. 4 – Not Calibrated

Issue description

The control lever for the number 4 rear electro-hydraulic remote (EHR) valve is not calibrated. The controller has lost the position data for the lever, which affects the proper operation of the remote valve. This fault can be triggered if the controller's power or ground is lost during a previous calibration attempt, if the controller memory fails, or if new software with different offset limits is installed.

Applies to these machines

  • T7 Series
  • T7 Standard Wheelbase
  • T7 Long Wheelbase
  • T7 Heavy-Duty
  • T9 Series
  • T9.390
  • T9.450
  • T9.505
  • T9.560
  • T9.615
  • T9.670
  • T6000 Series
  • T6080
  • TG Series

Check the cause

  1. Verify the EHR controller has a stable power and ground connection, as a loss of power during operation or calibration can trigger this fault

  2. Scan for other active fault codes (such as 4219 for the valve spool not being calibrated) to gather additional diagnostic clues

  3. Manually operate the remote lever to stroke the valve back and forth to clear any debris that might be impeding movement

  4. Inspect the wiring harness and connectors between the control lever, the EHR controller, and the remote valve for signs of damage, corrosion, or loose connections

Repair steps

  1. Access Calibration Menu

    Navigate to the calibration mode through the tractor's instrument cluster display or monitor (often labeled 'H' menu).

  2. Select the Valve

    Once in the calibration menu, select the remote valve that needs calibration (in this case, rear remote #4).

  3. Initiate Calibration

    Follow the on-screen prompts to start the calibration process. This typically involves moving the control lever to its full extend and retract positions as directed by the system.

  4. System Synchronization

    The controller will record the lever's position values. The process may involve the system automatically moving the valve spool to learn its limits.

  5. Save and Exit

    Once the calibration sequence is complete, ensure you exit the menu properly to save the new calibration values to the controller's memory.

  6. Troubleshoot Calibration Failure

    If the standard calibration procedure fails, repeat the calibration. Check for issues with the control lever potentiometer, as a worn or faulty potentiometer can prevent the system from getting a stable reading. In some cases, a special calibration tool that connects to the valve block may be required.

  7. Replace Control Lever Assembly

    If calibration repeatedly fails and the wiring is confirmed to be intact, the control lever assembly may need to be replaced.

Parts you might need

(9)
  • Rear Remote Electro-Hydraulic Control Lever / Potentiometer

    Specific part numbers are not available without the exact tractor model and serial number. It is recommended to contact a New Holland dealer with this information to source the correct part.

  • Remote Hydraulic Calibration Tool

    CAS 2806

    Mentioned as a required tool for 'AUX CAL' procedures.

  • Special Tool380001903

    Used for valve calibration on T9 series tractors.

  • Remanufactured part. Supersedes older part number 84184612. Used on various T8, T9, TG, Magnum, MX, and Steiger models.

  • Fits models like the T4020

  • Lever87358094
  • Lever

    86554976

    Remote control gear lever

  • Rear Remote Hydraulic Valve Kit

    MT20116103
  • Additional Rear Remote Valve Kit

    47929610

Get help to fix this fault by requesting a quote

Browse other New Holland codes