4181

New Holland 4181 – DU: Rear EHR Control No.4 Open Circuit

Issue description

The DU module has detected a loss of continuity (an open circuit) in the electrical circuit of the number 4 Electronic Hydraulic Remote (EHR) valve. This indicates a break or disconnection in the electrical path to the solenoid that actuates this specific remote valve, which can be caused by a broken wire, a loose or corroded connector, or a failed solenoid coil.

Applies to these machines

  • T4 Series
  • T4.95
  • T4.115
  • T5 Series
  • T6 Series
  • T7 Series
  • T7.210
  • T7.230
  • T7.245
  • T7.315
  • TN Series
  • TN95DA

Check the cause

  1. Visually inspect the wiring harness leading to the #4 rear EHR valve for physical damage, cuts, abrasions, or pinched/melted areas

  2. Disconnect and inspect the electrical connector for the #4 EHR solenoid for corrosion, dirt, or moisture, ensuring it is securely seated

  3. Check for other active fault codes, particularly communication errors (prefixed with 'U') or power supply faults, which could indicate a broader electrical issue rather than an isolated EHR valve problem

Repair steps

  1. Isolate the circuit

    Disconnect the tractor's battery to prevent electrical shorts.

  2. Test the solenoid

    Disconnect the electrical connector from the #4 EHR valve solenoid. Using a multimeter set to measure resistance (Ohms), probe the two pins on the solenoid itself. A reading of 'OL' or infinite resistance indicates an open circuit within the solenoid, meaning it has failed and needs replacement.

  3. Test the wiring harness

    With the solenoid and the DU module disconnected, use a multimeter to check for continuity on the wires running between the DU module and the #4 EHR valve connector. Each wire should show near-zero resistance from end to end. A reading of 'OL' indicates a break in that wire. Check for a short to ground by testing for continuity between each wire and the tractor chassis (should read 'OL').

  4. Repair or replace

    If a broken wire is found, repair it using an appropriate sealed connector or by soldering and heat-shrinking to protect the repair from moisture and vibration. If the solenoid is found to be open, replace it.

  5. Clear codes and calibrate

    After the repair is complete, reconnect the battery. Start the tractor and use the onboard diagnostic menu (often an 'H' routine) or a diagnostic tool to clear the fault codes. Perform a calibration of the EHR valve if required by the system.