New Holland 4190 – Armrest Controller / TCU: Rear Remote No. 1 No Communications
Issue description
The system indicates a complete loss of communication between the main vehicle controller and the electronic control module for the #1 rear Electro-Hydraulic Remote (EHR) valve over the CAN bus. The #1 remote valve module is offline and not receiving commands, rendering the #1 rear remote inoperative. This will directly affect the operation of any hydraulic functions controlled by this specific remote.
Applies to these machines
31 machines- T6010
- T6020
- T6030
- T6040
- T6050
- T6060
- T6070
- T6080
- T6.120 - T6.175
- T7.170
- T7.185
- T7.200
- T7.210
- T7.220
- T7.235
- T7.250
- T7.260
- T7.270
- T7.290
- T7.315
- T8.275
- T8.300
- T8.320
- T8.330
- T8.360
- T8.380
- T8.390
- T8.410
- T8.435
- T9.390
- T9.615
Check the cause
Visually inspect the wiring harness leading to the rear remote valve stack for chafing, cuts, pinching, or heat exposure.
Check the electrical connector on the #1 remote valve to ensure it is fully seated, secure, and free of dirt, moisture, corrosion, or bent/pushed-out pins.
Perform a CAN Bus Resistance Check (Key OFF, battery disconnected): measure resistance between CAN High and CAN Low at the diagnostic port or EHR CAN bus connector. It should read approximately 60 Ohms. 120 Ohms indicates an open circuit or missing resistor; significantly lower indicates a short.
Perform a practical isolation test by swapping the electrical connectors between remote valve #1 and an adjacent working remote (e.g., remote #2). If the fault code changes to 4191, the electronic module on the #1 valve is faulty. If it remains 4190, the issue is in the wiring harness or main controller.
Repair steps
Confirm the Fault
Verify that fault code 4190 is active and that the #1 rear remote is unresponsive.
Perform Diagnostics
Complete the diagnostic checks listed above to rule out wiring, connector, or CAN bus network issues.
Isolate the Faulty Component
Based on the diagnostic results, determine if the fault lies with the wiring or the #1 EHR valve module itself.
Repair or Replace
If the wiring harness is found to be damaged, repair the affected wires, ensuring connections are sealed against moisture. If the connector is corroded or damaged, replace the connector and pins. If the #1 EHR valve module is identified as the faulty component, it must be replaced. The electronic module is typically mounted directly on the hydraulic valve section.
Clear Codes and Test
After the repair or replacement, clear all fault codes using the tractor's diagnostic menu or an electronic service tool. Operate the #1 remote valve to ensure it is communicating and functioning correctly. A calibration of the new remote may be required.
Parts you might need
(8)For various New Holland T6, T7, and Case IH Maxxum/Puma models
Rexroth/CNH part for T7000 series and other models
- Right-hand remote valve47595558
For New Holland T8 and Case IH Magnum tractors
Right-hand remote valve
87486189For New Holland T8 and Case IH Magnum tractors
Electronic Rear Remote Valve - Position 5
719412184Valves for specific positions can sometimes be ordered
Electronic Rear Remote Valve - Position 5
719412224Valves for specific positions can sometimes be ordered
Replaces older iterations including 47434173, 47434176, 47592926, 47723762, 51443155, and 87330385.
EHR Control Valve Wire Harness
84158327If the communication loss is due to a failed harness segment at the valve.
Get help to fix this fault by requesting a quote