4305

New Holland 4305: Rear remote control valve No. 6 - low voltage

Issue description

The system has detected low voltage in the rear remote control valve No. 6. This may affect the proper operation of the component.

Check the cause

  1. The power supply to the rear remote control valve No. 6

  2. Wiring connections to the rear remote control valve No. 6

  3. The voltage level at the rear remote control valve No. 6

Repair steps

  1. Verify the power supply

    Check the power source and ensure it is providing the correct voltage to the rear remote control valve No. 6.

  2. Inspect wiring connections

    Examine the wiring and connections to the rear remote control valve No. 6 for any damage, looseness, or corrosion.

  3. Measure voltage

    Use a multimeter to measure the voltage at the rear remote control valve No. 6 and compare it to the expected value.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes