New Holland 4313 – TCU: Rear Remote No. 6 Unable to Reach Neutral
Issue description
The electro-hydraulic remote (EHR) valve for the sixth rear remote has failed to return to its neutral position. The Tractor Control Unit (TCU) has detected that the valve spool is stuck in either the raise or lower position when it should be centered. This can be caused by a loss of calibration, electrical circuit issues, hydraulic fluid contamination, or internal mechanical binding.
Applies to these machines
9 machines- T8.275
- T8.300
- T8.330
- T8.360
- T8.390
- T8.410
- T8.420
- T8.435
- T9 Series
Check the cause
Visually inspect the #6 remote valve, its electrical connectors, and the wiring harness for any visible damage, corrosion, or loose connections
Check the hydraulic fluid level and condition, as contaminated or low fluid can cause erratic valve behavior
Attempt to manually cycle the valve by operating the remote lever back and forth to clear any potential debris causing the spool to stick
Repair steps
Attempt valve recalibration
Warm the hydraulic oil to a minimum operating temperature of approximately 49°C (120°F). Navigate to the diagnostics or calibrations menu on the instrument cluster or IntelliView monitor, select the EHR or remote valve calibration, and follow the on-screen prompts to calibrate remote valve #6. On some models, this may require a special diagnostic tool to enter the calibration mode.
Diagnose electrical system
If calibration fails, test the solenoid on remote valve #6 for correct resistance and voltage supply. Compare the readings to a known good solenoid on an adjacent remote valve. A significant difference in resistance or a lack of voltage when the remote is activated indicates a faulty solenoid or a problem in the wiring harness. Disconnect the main harness from the #6 remote valve and check for continuity and for shorts between wires or to ground. Repair damaged wires or corroded pins.
Disassemble and repair valve
If electrical components test correctly, the spool is likely mechanically or hydraulically stuck due to contamination, internal wear, or damaged seals causing internal leakage. Remove the valve from the valve stack, disassemble the valve slice, clean all components, and replace all seals and O-rings with a new seal kit. Pay close attention to the order of shims and internal components during disassembly.
Parts you might need
(5)Remote Valve (Slice #6)
92656698Supersedes 91775616. The entire kit for adding a 6th remote is part number 91903139.
- Solenoid Valve5192014
4-Watt Solenoid Valve. Alternate part number 48055262 may apply depending on model.
Seal Kit, Between Sections
51641948For servicing the valve sections.
Seal Kit, Valve Section to Coupler
51641949For servicing the valve sections.
Hydraulic Relief Valve Seal Kit
86508168General hydraulic relief valve seal kit.