New Holland 4315 – EHR: Rear Remote No.7 - No EHR Control Messages
Issue description
The tractor's CAN bus network has lost communication with the 7th rear electro-hydraulic remote (EHR) valve. The main controller is not receiving the expected electronic control messages from this specific valve slice. This typically indicates an open circuit in the CAN wiring, a disconnected plug, a failed electronic module on the valve itself, or a software configuration error.
Applies to these machines
10 machines- T8.275
- T8.300
- T8.330
- T8.360
- T8.390
- T8.420
- Magnum 235
- Magnum 340
- T7000 Series
- T9 Series
Check the cause
Check for other simultaneous fault codes, which may indicate a broader network issue or low battery voltage
Inspect battery voltage (ideally 12.6V) and ensure chassis and cab ground straps are clean and secure
Perform a CAN Bus power-off test: measure resistance across CAN_H and CAN_L (should be ~60 Ohms; 120 Ohms indicates an open circuit/missing resistor, lower indicates a short)
Perform a CAN Bus power-on test: measure DC voltage of CAN_H and CAN_L to ground (both should be ~2.5V when idle)
Visually inspect the wiring harness and connectors between the armrest controller and the #7 rear remote valve, especially at articulation points and the plug under the right-hand cab above the battery box
Isolate the component by swapping the electrical connector from remote valve #7 with an adjacent functioning remote (e.g., #6 or #8) to see if the fault code follows the valve or stays with the wiring
Repair steps
Repair wiring and connectors
If damaged wiring or corroded connectors were found during diagnosis, repair or replace them and ensure all connections are clean and secure.
Replace remote valve electronic module
If the fault is isolated to the #7 remote valve itself, disconnect the electrical connector, unbolt the electronic module (pilot head) from the valve block, install the new module ensuring seals are seated, and reconnect.
Replace armrest controller
If diagnostics point to the armrest controller, disconnect the battery, disassemble the armrest, disconnect all electrical connectors, install the new unit, and reconnect wiring.
Perform system calibration
After replacing either the remote valve module or the armrest controller, perform a calibration procedure using the tractor's instrument cluster display or an Electronic Service Tool (EST) so the system recognizes the new component.
Parts you might need
(11)Rear Remote Hydraulic Valve Kit
MT20116103Complete valve kit; verify fitment by serial number
Two-Spool Remote Valve Kit
710440016Verify fitment by serial number
Valve Assembly (Older Case IH)
1980311C6Verify fitment by serial number
Valve Assembly (Older Case IH Alternative)
186760A6Verify fitment by serial number
Armrest Controller (Remanufactured)
84165726RVerify fitment by serial number
Armrest Controller (T7000 Series)
87399131Fits some T7000 series tractors
Armrest Controller (T9 Series)
84366982Fits some T9 series tractors
- Armrest Controller (General)87536543
General armrest part
Electro-Hydraulic Rear Remote Valve Section / EHR Valve Slice
47675278Exact slice numbers for T8/T9 stacks require a serial number lookup. Requires software configuration and calibration via the CNH EST tool after physical installation.
Electro-Hydraulic Rear Remote Valve Section / EHR Valve Slice
719195010Exact slice numbers for T8/T9 stacks require a serial number lookup. Requires software configuration and calibration via the CNH EST tool after physical installation.
Exact slice numbers for T8/T9 stacks require a serial number lookup. Requires software configuration and calibration via the CNH EST tool after physical installation.
Get help to fix this fault by requesting a quote