4361
New Holland 4361 – UCM: Ground Drive: Solenoid Right (A) Supply Open Circuit
Issue description
The fault code indicates an open circuit in the supply circuit for the Solenoid Right (A) in the Ground Drive system. This condition prevents proper operation of the component connected to this circuit.
Check the cause
The wiring and connections associated with the Solenoid Right (A)
The power supply to the Solenoid Right (A)
The integrity of the circuit from the controller to the Solenoid Right (A)
Repair steps
Inspect
Check the wiring and connections for the Solenoid Right (A) for damage, corrosion, or disconnection.
Test
Verify the power supply to the Solenoid Right (A) using a multimeter or appropriate testing device.
Repair
If an open circuit is found, repair or replace the affected wiring or connections.
Parts you might need
(0)Get help to fix this fault by requesting a quote