New Holland 4514 – ACM: Front Remote No.2 No Signal

Issue description

The system has detected that no control message has been received for the front remote control valve No. 2. This indicates a CAN bus communication failure between the main operator interface (typically the armrest controller) and the valve's electronic control module, preventing the valve from receiving commands and rendering it non-functional.

Applies to these machines

  • T7.220
  • T7.235
  • T7.250
  • T7.260
  • T7.270
  • T8030
  • TG245

Check the cause

  1. Perform a visual inspection of the wiring harness leading to the front remote valves for rubbing, chafing, pinching, or corrosion, especially where the harness passes under the cab or connects to the armrest.

  2. Inspect electrical connectors for front remote valve #2 and the armrest controller for corroded, bent, or pushed-out pins. Clean the connectors and ensure a secure connection.

  3. Check battery voltage and charging system function, as low voltage can cause communication ghost codes.

  4. Perform a CAN bus integrity check with the key off (expect approximately 60 ohms between CAN High and Low; 120 ohms indicates a faulty or missing terminating resistor).

  5. Check CAN bus voltage with the key on (CAN High should be 2.5-3.5V, CAN Low 1.5-2.5V).

  6. Perform a wiggle test on the wiring harness with the system powered on, particularly at the connectors and along the frame, to check for intermittent connections.

Repair steps

  1. Isolate the faulty component

    Swap the electrical connector from remote #2 with a known working remote (e.g., #1 or #3). If the fault code changes to indicate a failure on the other remote (e.g., 4100), this suggests the issue lies with the control module on the valve itself. If the fault remains on remote #2, the problem is likely in the wiring harness between the armrest controller and the valve.

  2. Repair wiring harness

    If a break or corrosion is found in the wiring harness, repair the affected wires and ensure all repairs are sealed against moisture. For intermittent issues where a wire is broken internally without visible damage, perform a continuity test on each wire in the circuit.

  3. Replace CAN bus terminator

    If the CAN bus resistance measured 120 ohms, replace the faulty terminating resistor.

  4. Replace valve control module or solenoid

    If the fault was isolated to the valve assembly during the swap test, replace the electronic control module or solenoid on the valve.

  5. Replace Armrest Controller

    If wiring and valve components are verified good, replace the armrest controller (rare).

Parts you might need

(13)
  • Used on some T7 and TM series tractors

  • Remote Valve Assembly/Control Module

    84175407
  • Remote Valve Assembly/Control Module

    87653270

    Used on some skid steer models, for reference

  • Remote Valve Assembly/Control Module (Bosch)

    521 610 025

    Bosch Part Number (for reference)

  • For T8030, for reference

  • For T8030, for reference

  • For reference on a T7.270

  • Electronic Mid Mount Kit (2 Valves + Joystick)

    719980024

    For reference on a T7.270

  • Armrest Control / EHR Control

    87648539

    Fits T6000 Series

  • General fitment

  • Fits T6/T7 Series

  • Fits T6/T7 Series

  • Illustrative of CNH valve parts

Get help to fix this fault by requesting a quote

Browse other New Holland codes