New Holland 4518 – ARM/ARU or EHR: Front valve remote control No. 2 voltage drop
Issue description
The control module has detected insufficient voltage (a voltage drop) in the electrical circuit for the solenoid that operates the front remote valve number 2. This condition may affect the proper operation of the remote valve and is typically caused by high resistance in the circuit, a failing solenoid component, or a poor electrical connection.
Applies to these machines
5 machines- T-Series (T6, T7, T8)
- WORKMASTER™ Series
- Boomer™ Series
- Loader Backhoes
- Skid Steers
Check the cause
Inspect the wiring harness leading to the front remote valve block (specifically solenoid #2) for chafing, pinching, corrosion, or breaks in the insulation.
Test battery and charging system health; ensure voltage is at least 12.6V at rest and that all battery terminals and chassis ground connections are clean and tight.
Perform a 'click test' by having an assistant operate the front remote #2 control while listening or feeling for the solenoid to actuate at the hydraulic valve block.
Disconnect the electrical connector for the #2 front remote solenoid and inspect the pins and sockets for corrosion, moisture, or pushed-out pins. Clean and apply dielectric grease.
Repair steps
Test solenoid voltage
Reconnect the solenoid connector. Using a multimeter with back-probe pins, measure the DC voltage across the two terminals while an assistant activates the remote control lever. Voltage should be close to system voltage (12V or 24V). A significantly lower reading confirms a voltage drop upstream. If no voltage is present, the issue could be a broken wire, a faulty controller, or a blown fuse.
Test solenoid coil resistance
Disconnect the solenoid connector and measure resistance between the two pins on the solenoid. A typical 12V coil should read between 3 and 30 Ohms. A reading of 'OL' (infinite) indicates an open circuit, and near-zero indicates a short circuit.
Test for shorts to ground
With the solenoid disconnected, measure resistance from each pin on the harness side of the connector to a clean chassis ground. There should be no continuity (infinite resistance). A low resistance reading indicates a short circuit in the wiring harness that must be repaired.
Replace faulty components
Replace the solenoid if it failed the resistance test. Repair or replace the wiring harness if damaged or shorted. If the solenoid and wiring are good but voltage from the controller is low or absent, the issue may lie with the armrest controller itself. This can sometimes be due to internal component failure, such as shorted filter caps or a bad crystal oscillator. Repairing controllers is a specialized task, and replacement is often the more practical solution.
Parts you might need
(9)- Solenoid, Control Valve84128131
Replaces 87445987. Verify fitment with serial number.
Solenoid, Control Valve
87445987Replaced by 84128131. Verify fitment with serial number.
- Solenoid, Control Valve87701329
Verify fitment with serial number.
Solenoid, Control Valve
85827994Verify fitment with serial number.
Solenoid, Control Valve
84151310Verify fitment with serial number.
Remote Valve Assembly
710440016Two-Spool Kit. In some cases, particularly on older models, the solenoid may not be sold separately from the valve section or 'slice'.