4731

New Holland 4731 – UCM: Ground Drive Pin A Short to Ground / Open Circuit

Issue description

The Universal Control Module (UCM) has detected an abnormal electrical signal from the component connected to Pin A of the ground drive circuit. This indicates either a short to ground, where current unintentionally flows to the chassis, or an open circuit, where the connection between the UCM and the component is broken. This fault can result in a loss of ground drive control and potential machine immobility.

Applies to these machines

  • L213
  • L215
  • L218
  • L220
  • L221
  • L223
  • L225
  • L228
  • L230
  • C227
  • C232
  • C238

Check the cause

  1. Visually inspect the wiring harness leading to the ground drive components for chafing, cuts, melted insulation, corrosion, bent pins, or loose connections.

  2. Check for a short to ground: Disconnect the harness from the suspected component and measure resistance between Pin A and a clean chassis ground. A low resistance reading indicates a short.

  3. Check for an open circuit: Measure continuity between Pin A at the component connector and Pin A at the UCM connector. No continuity indicates a broken wire.

  4. Measure the resistance across the pins of the ground drive component itself and compare to service manual specifications to identify internal component failure.

Repair steps

  1. Prepare machine for service

    Park the machine on a level surface, lower the attachments, engage the parking brake, turn off the engine, and disconnect the battery.

  2. Access UCM and ground drive components

    Tilt the cab as needed to access the Universal Control Module (UCM) and the ground drive components located on the hydrostatic pump assembly.

  3. Repair or replace wiring harness

    If a short or open circuit is found during testing, repair the damaged wire section and seal it properly, or replace the entire wiring harness if the damage is extensive.

  4. Replace faulty ground drive component

    If wiring tests pass but the component resistance is out of specification, replace the faulty ground drive component (e.g., solenoid) with a new OEM part.

  5. Reconnect and verify repair

    Reconnect all connectors and the battery. Start the machine, verify the fault code has cleared, and operate the ground drive to ensure proper function.

Parts you might need

(11)
  • Universal Control Module (UCM)

    84267444

    For L223 and similar models

  • Actia, OEM for New Holland

  • Ground Drive Solenoid

    87030707

    Fits various models including L150, L175, C175

  • Fits various models including L180, L185, L190

  • Fits various models including LS180, LX885

  • Verify fitment by serial number

  • Chassis Wire Harness

    84383805

    For EH LG models

  • Cab Wire Harness

    84352385

    For EH Basic models

  • May be related to ground drive faults

  • Magnetic Ground Speed Sensor

    86030257

    May be related to ground drive faults

  • Swash Plate Angle Sensor

    84356794

    Mounts directly to the Bosch Rexroth hydrostatic pump. Mounting screws are NSS (Not Serviced Separately) and must be reused or procured locally.

Get help to fix this fault by requesting a quote