New Holland 4731 – UCM: Ground Drive Pin A Short to Ground / Open Circuit
Issue description
The Universal Control Module (UCM) has detected an abnormal electrical signal from the component connected to Pin A of the ground drive circuit. This indicates either a short to ground, where current unintentionally flows to the chassis, or an open circuit, where the connection between the UCM and the component is broken. This fault can result in a loss of ground drive control and potential machine immobility.
Applies to these machines
12 machines- L213
- L215
- L218
- L220
- L221
- L223
- L225
- L228
- L230
- C227
- C232
- C238
Check the cause
Visually inspect the wiring harness leading to the ground drive components for chafing, cuts, melted insulation, corrosion, bent pins, or loose connections.
Check for a short to ground: Disconnect the harness from the suspected component and measure resistance between Pin A and a clean chassis ground. A low resistance reading indicates a short.
Check for an open circuit: Measure continuity between Pin A at the component connector and Pin A at the UCM connector. No continuity indicates a broken wire.
Measure the resistance across the pins of the ground drive component itself and compare to service manual specifications to identify internal component failure.
Repair steps
Prepare machine for service
Park the machine on a level surface, lower the attachments, engage the parking brake, turn off the engine, and disconnect the battery.
Access UCM and ground drive components
Tilt the cab as needed to access the Universal Control Module (UCM) and the ground drive components located on the hydrostatic pump assembly.
Repair or replace wiring harness
If a short or open circuit is found during testing, repair the damaged wire section and seal it properly, or replace the entire wiring harness if the damage is extensive.
Replace faulty ground drive component
If wiring tests pass but the component resistance is out of specification, replace the faulty ground drive component (e.g., solenoid) with a new OEM part.
Reconnect and verify repair
Reconnect all connectors and the battery. Start the machine, verify the fault code has cleared, and operate the ground drive to ensure proper function.
Parts you might need
(11)Universal Control Module (UCM)
84267444For L223 and similar models
- Universal Control Module (UCM)47385274
Actia, OEM for New Holland
Ground Drive Solenoid
87030707Fits various models including L150, L175, C175
- Ground Drive Solenoid84128131
Fits various models including L180, L185, L190
- Ground Drive Solenoid83981012
Fits various models including LS180, LX885
- Ground Drive Solenoid84273815
Verify fitment by serial number
Chassis Wire Harness
84383805For EH LG models
Cab Wire Harness
84352385For EH Basic models
- True Ground Speed Row Sensor87733890
May be related to ground drive faults
Magnetic Ground Speed Sensor
86030257May be related to ground drive faults
Swash Plate Angle Sensor
84356794Mounts directly to the Bosch Rexroth hydrostatic pump. Mounting screws are NSS (Not Serviced Separately) and must be reused or procured locally.
Get help to fix this fault by requesting a quote