New Holland 4735: Hydraulic Motor: Signal from Potentiometer Short to Ground or Open Circuit

Issue description

The fault code indicates an issue with the signal from the potentiometer in the hydraulic motor, specifically a short to ground or an open circuit.

Check the cause

  1. The wiring connections of the potentiometer

  2. The integrity of the potentiometer signal circuit

  3. The condition of the potentiometer itself

Repair steps

  1. Inspect

    Inspect the wiring connections of the potentiometer for any signs of damage, wear, or poor contact.

  2. Test

    Test the integrity of the potentiometer signal circuit for continuity and proper resistance.

  3. Replace

    If the potentiometer is found to be faulty, replace it with a compatible component.