4735
New Holland 4735: Hydraulic Motor: Signal from Potentiometer Short to Ground or Open Circuit
Issue description
The fault code indicates an issue with the signal from the potentiometer in the hydraulic motor, specifically a short to ground or an open circuit.
Check the cause
The wiring connections of the potentiometer
The integrity of the potentiometer signal circuit
The condition of the potentiometer itself
Repair steps
Inspect
Inspect the wiring connections of the potentiometer for any signs of damage, wear, or poor contact.
Test
Test the integrity of the potentiometer signal circuit for continuity and proper resistance.
Replace
If the potentiometer is found to be faulty, replace it with a compatible component.
Parts you might need
(0)Get help to fix this fault by requesting a quote