4744

New Holland 4744 – UCM: Ground Drive: Pin B Short to Ground or Open Circuit

Issue description

The fault code indicates an issue with the Ground Drive related to Pin B, either a short to ground or an open circuit. This may affect the proper operation of the component associated with Pin B in the Ground Drive system.

Check the cause

  1. Pin B wiring for damage or corrosion

  2. Connections related to Pin B for looseness or disconnection

  3. Continuity of the circuit associated with Pin B

Repair steps

  1. Inspect

    Inspect the wiring for Pin B for any signs of damage, wear, or corrosion.

  2. Check

    Check the connections for Pin B to ensure they are secure and properly seated.

  3. Test

    Test the continuity of the circuit associated with Pin B using a multimeter or appropriate testing equipment.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes