4790

New Holland 4790: Proportional Valve X-Axis: Valve MMX-A Solenoid Short to 12V

Issue description

The fault code indicates a short circuit in the solenoid of the Proportional Valve X-Axis, specifically the Valve MMX-A, where the solenoid is shorted to 12V.

Check the cause

  1. The solenoid of the Proportional Valve X-Axis

  2. The wiring connected to the solenoid of the Proportional Valve X-Axis

  3. The connection points of the solenoid to the 12V power supply

Repair steps

  1. Inspect

    Inspect the solenoid of the Proportional Valve X-Axis for visible damage or signs of shorting.

  2. Test

    Test the solenoid of the Proportional Valve X-Axis for continuity and resistance using a multimeter.

  3. Check

    Check the wiring and connections of the solenoid of the Proportional Valve X-Axis for any damage or poor contact.