New Holland 4793: Proportional Valve Y-Axis: Valve MMY-B Solenoid Short to 12V

Issue description

The fault code indicates a short circuit in the solenoid of the Proportional Valve Y-Axis, specifically the Valve MMY-B, which is connected to 12V.

Check the cause

  1. The solenoid of the Proportional Valve Y-Axis

  2. The wiring connected to the solenoid of the Proportional Valve Y-Axis

  3. The connection points of the solenoid to the 12V power source

Repair steps

  1. Inspect

    Inspect the solenoid of the Proportional Valve Y-Axis for visible damage or signs of shorting.

  2. Test

    Test the solenoid of the Proportional Valve Y-Axis for continuity and resistance using a multimeter.

  3. Check

    Check the wiring and connections of the solenoid of the Proportional Valve Y-Axis for any damage or poor contact.