4793
New Holland 4793: Proportional Valve Y-Axis: Valve MMY-B Solenoid Short to 12V
Issue description
The fault code indicates a short circuit in the solenoid of the Proportional Valve Y-Axis, specifically the Valve MMY-B, which is connected to 12V.
Check the cause
The solenoid of the Proportional Valve Y-Axis
The wiring connected to the solenoid of the Proportional Valve Y-Axis
The connection points of the solenoid to the 12V power source
Repair steps
Inspect
Inspect the solenoid of the Proportional Valve Y-Axis for visible damage or signs of shorting.
Test
Test the solenoid of the Proportional Valve Y-Axis for continuity and resistance using a multimeter.
Check
Check the wiring and connections of the solenoid of the Proportional Valve Y-Axis for any damage or poor contact.
Parts you might need
(0)Get help to fix this fault by requesting a quote