Issue description

The electronic control module has detected that the rear Power Take-Off (PTO) brake solenoid is remaining energized when it should not be. The PTO brake is designed to stop the rotation of the PTO shaft when disengaged. A stuck-on condition is typically caused by an electrical short to a 12V source or a failure within the control module itself, which may prevent the PTO system from engaging correctly or cause it to slip under load.

Applies to these machines

  • 120 to 155 Range Command
  • TM115
  • TM125
  • TM135
  • TM150
  • TM165
  • T7.210
  • TD5
  • Case Farmall

Check the cause

  1. Visually inspect the wiring harness and connectors leading to the rear PTO brake solenoid for any signs of damage, corrosion, or loose connections

  2. Test the wiring for a short to a 12-volt power source (a primary suspected cause of the stuck-on condition)

  3. Disconnect the solenoid and test its resistance to ensure it is within the manufacturer's specified range to rule out an internal short or open circuit

  4. With the key on and the PTO disengaged, check for voltage at the solenoid connector. There should be no voltage present; if there is, it indicates a wiring short or a control module problem

  5. Using a compatible electronic service tool, attempt an actuation test to see if the solenoid responds to commands from the control module

Repair steps

  1. De-energize the system

    Turn off the tractor and disconnect the battery to prevent electrical shorts before beginning repairs.

  2. Locate the solenoid

    Find the rear PTO brake solenoid, which is typically located on the rear of the tractor near the PTO housing and hydraulic control valves.

  3. Repair wiring

    If diagnostic checks revealed a short to 12V, damaged wiring, or corroded connectors, repair or replace the affected harness sections.

  4. Replace the solenoid

    If the solenoid fails resistance testing, disconnect its electrical connector and hydraulic lines (if applicable). Unbolt and remove the old solenoid. Install the new solenoid, ensuring all seals and O-rings are correctly seated, then reconnect the lines.

  5. Clear Fault Codes

    After the repair is complete, reconnect the battery, start the tractor, and use an electronic service tool or the vehicle's diagnostic menu to clear the fault codes.

  6. Test Operation

    Engage and disengage the rear PTO multiple times to ensure it is functioning correctly and that the fault code does not reappear.