50070

New Holland 50070 – MIU: Corrupt Minimum Frame Height Calibration Value in Non-Volatile Memory

Issue description

The stored data for the header's minimum height setting has become corrupted or is unreadable within the system's non-volatile memory. This minimum height value is a critical parameter for the proper functioning of the automatic header height control system. When this data is corrupt, the system can no longer reliably determine the lowest point of the header's operational range, which can lead to erratic behavior or disablement of the auto-height function.

Applies to these machines

  • CR920
  • CR940
  • CR960
  • CR970
  • CR980
  • CR6.80
  • CR6.90
  • CR7.90
  • CR7090
  • CR8.90
  • CR8090
  • CR9060
  • CR9070
  • CR9080
  • CR10.90
  • CR11
  • CX840
  • CX880

Check the cause

  1. Check for other active fault codes, especially those related to header height sensors (right, center, or left), before attempting calibration

  2. Inspect header height sensors (mechanical feelers/skid plates or ultrasonic sensors) for any signs of physical damage, such as bent plates or broken components

  3. Check the wiring harnesses connected to the sensors for frayed wires, corrosion, or loose connections

  4. Verify that any mechanical linkages associated with the height sensors are free to move and not binding, and check that the sensor arm has adequate room for movement and rotates freely

  5. Warm up the combine's hydraulic oil to operating temperature before calibration and inspect hydraulic components for visible leaks

  6. Ensure proper machine setup: park the combine on a level surface with the header attached and level to the ground, engine running, and header/feeder disengaged

Repair steps

  1. Access the Calibration Menu

    From the main screen on the combine's display (e.g., IntelliView or Pro 700), navigate to the 'Calibrations' menu and select 'Header'.

  2. Initiate the Calibration

    The system will display a series of on-screen prompts. Acknowledge any safety warnings about the header moving automatically.

  3. Calibrate Minimum Height

    When instructed by the display, 'pulse' the header down switch. The header will lower until it touches the ground, and the system will record this as the minimum height value.

  4. Calibrate Maximum Height

    Following the minimum height calibration, the system will prompt you to 'pulse' the header up switch. The header will raise to its maximum height, and the system will record this value.

  5. Calibrate Pressure Thresholds

    If prompted by the system, pulse the header down again to determine the pressure thresholds for the header lower valve.

  6. Complete the Calibration

    Follow any remaining on-screen prompts until the display indicates 'Calibration Successful' or 'Calibration Completed', then exit the menu. If the calibration fails or the fault code returns, re-check sensor and wiring integrity, or consider replacing the MIU controller.

Parts you might need

(5)
  • OEM part number for CR series combines (including CR9070). Verify correct part number for your specific machine model and serial number with an authorized dealer.

  • Generic Control Unit

    91858049

    Specific application as the MIU is not confirmed.

  • Generic Control Unit

    SBA385870641

    Specific application as the MIU is not confirmed.

  • Generic Control Unit

    MT40349972

    Specific application as the MIU is not confirmed.

  • Listed for CR9070 electrical systems. Specific function as a height sensor requires dealer confirmation based on serial number.

Get help to fix this fault by requesting a quote

Browse other New Holland codes