5008
New Holland 5008 – New Holland Rear Power Take Off: Both PTO On and Off Switches Activated Simultaneously
Issue description
The fault code indicates that both the PTO on and off switches are simultaneously on, and one of the PTO switches is shorted to 12 volts. This condition suggests an electrical fault in the PTO switch circuit.
Check the cause
Both PTO on and off switches
The wiring connected to the PTO switches
The voltage level at the PTO switches
Repair steps
Inspect
Check both PTO on and off switches for physical damage or signs of shorting.
Test
Use a multimeter to measure the voltage at each PTO switch to confirm if one is shorted to 12 volts.
Verify
Ensure that the PTO on and off switches are not both activated at the same time during normal operation.
Parts you might need
(0)Get help to fix this fault by requesting a quote