5008
New Holland 5008 – Rear PTO: Both PTO On and Off switches are simultaneously on
Issue description
The fault indicates that both the PTO On and Off switches are active at the same time. This condition suggests that one of the switches is shorted to 12 volts, causing a conflict in the signal.
Check the cause
The condition of the PTO On switch
The condition of the PTO Off switch
The wiring and connections related to the PTO switches
Repair steps
Inspect the PTO On switch
Check for physical damage or signs of shorting to 12 volts.
Inspect the PTO Off switch
Check for physical damage or signs of shorting to 12 volts.
Test the wiring and connections
Verify that the wiring and connections to the PTO switches are intact and not causing a short.
Parts you might need
(0)Get help to fix this fault by requesting a quote