New Holland 5016 – Rear PTO: PTO Speed Detected Without Engine RPM

Issue description

The Rear PTO controller is detecting a rotational speed from the PTO speed sensor even though the PTO is switched off and the engine is not running. This is an illogical state, as the PTO shaft should be stationary under these conditions. The system flags this error to prevent unexpected PTO operation and potential safety hazards. The underlying cause is typically an electrical fault that sends a false speed signal to the control module.

Applies to these machines

  • T4
  • T5
  • T7
  • T8
  • T6030
  • T6050
  • T6070
  • T6080
  • TM140
  • 5640
  • 6640
  • 7740
  • 8340

Check the cause

  1. Verify battery voltage is above 12.6V and ensure all chassis and controller ground connections are clean and tight, as low voltage can cause 'ghost' codes.

  2. Inspect the wiring harness leading to the PTO speed sensor and PTO solenoid for chafing, corrosion, or melted insulation (pay special attention near the rear of the tractor, fuel tank, and under rear lights).

  3. With the PTO switch in the 'OFF' position, check for voltage at the PTO solenoid. The presence of voltage indicates a short in the wiring or a faulty PTO switch.

  4. Test the PTO speed sensor (magnetic pickup) for resistance and AC voltage output while rotating the PTO shaft. An open circuit (infinite resistance) or short circuit (near zero resistance) indicates a faulty sensor.

Repair steps

  1. Repair wiring harness

    If damaged wiring or corroded connectors are found during the visual inspection, repair or replace the affected sections of the harness. Ensure all connections are clean and secure.

  2. Test or replace PTO solenoid

    If voltage is incorrectly present at the solenoid, or if it is suspected faulty, briefly apply 12V directly to the terminals with the tractor off to listen for a mechanical 'click'. Test the resistance of the solenoid coil. Replace the solenoid if it fails these tests.

  3. Replace PTO speed sensor

    If diagnostic tests indicate a faulty sensor, replace it. It is typically located on the rear transmission or PTO housing. Be prepared for oil to drain. On some models (e.g., Workmaster series), a protective cover must be removed to access the sensor.

  4. Replace PTO control module

    If all other components and wiring have been tested and found to be in good working order, replace the Rear PTO control module. This is generally the last component to replace due to cost.

Parts you might need

(9)
  • CNH OEM part. Monitors the rotational speed of the PTO shaft.

  • Fits various New Holland T5, T6, and T7 series tractors.

  • Fits New Holland TG series tractors. Alternative part number: 411897A2.

  • Listed for New Holland Agriculture.

  • Listed for New Holland Construction equipment but may have agricultural applications.

  • Fits New Holland 40 series (5640, 6640, 7740, 7840, 8240, 8340). Alternative part numbers: 81864314, 81867013, F0NN94044N90AA, F0NN94044N90BA, F0NN94044N90BB.

  • PTO Control Support

    5177068

    Fits various TN series tractors.

  • PTO Switch Mounting Support

    87392040

    Listed for New Holland TT45A.

  • Fits New Holland TN55 and TN65.

Get help to fix this fault by requesting a quote