5121
New Holland 5121 – UCM: Boom Raise/Lower Circuit Issue
Issue description
The fault code indicates a problem with the Boom Raise/Lower circuit, specifically a short to power, a short to ground, or an open circuit.
Check the cause
The wiring associated with the Boom Raise/Lower function
Connections related to the Boom Raise/Lower circuit
The component identified by this code
Repair steps
Inspect
Inspect the wiring and connections for the Boom Raise/Lower circuit for damage, wear, or loose connections.
Test
Test the Boom Raise/Lower circuit for short to power, short to ground, or open circuit using a multimeter or diagnostic tool.
Repair
Repair or replace any damaged wiring, connectors, or the component identified by this code as necessary.
Parts you might need
(0)Get help to fix this fault by requesting a quote