520208-04

New Holland 520208-04: WHEEL_GROUND_SPD_1 Fault with Voltage Below Normal or Shorted to Low Source

Issue description

The system has detected an issue with the WHEEL_GROUND_SPD_1 signal, indicating that the voltage is below normal or there is a short to a low source. This may affect the proper operation of the component associated with this signal.

Check the cause

  1. WHEEL_GROUND_SPD_1 circuit

  2. Voltage levels at the WHEEL_GROUND_SPD_1 connection

  3. Potential short to low source in the wiring or component

Repair steps

  1. Inspect

    Inspect the WHEEL_GROUND_SPD_1 circuit for any visible damage, loose connections, or signs of shorting.

  2. Measure

    Measure the voltage at the WHEEL_GROUND_SPD_1 connection to confirm if it is below normal or shows signs of a short to a low source.

  3. Test

    Test the WHEEL_GROUND_SPD_1 component for proper functionality using the service manual procedures.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes