520237-04
New Holland 520237-04: Valve Solenoid 2E Voltage below normal, or shorted to low source
Issue description
The system has detected an issue with Valve Solenoid 2E, where the voltage is below normal or there is a short to a low source. This may affect the proper operation of the component.
Check the cause
Valve Solenoid 2E
Wiring connected to Valve Solenoid 2E
Power supply to Valve Solenoid 2E
Repair steps
Inspect
Check the physical condition of Valve Solenoid 2E for signs of damage or wear.
Test
Measure the voltage at Valve Solenoid 2E to confirm it is within the expected range.
Inspect
Examine the wiring and connections to Valve Solenoid 2E for any signs of damage, corrosion, or poor contact.
Test
Check for a short to a low source in the circuit connected to Valve Solenoid 2E.
Parts you might need
(0)Get help to fix this fault by requesting a quote