520237-05
New Holland 520237-05: Valve Solenoid 2E Current below normal, or open circuit
Issue description
The system has detected that the current for Valve Solenoid 2E is below normal or there is an open circuit in the circuit.
Check the cause
Valve Solenoid 2E
the affected circuit
Repair steps
Inspect
Inspect Valve Solenoid 2E for physical damage or signs of wear.
Test
Test the electrical connection and continuity of the affected circuit.
Replace
If damage or malfunction is found, replace Valve Solenoid 2E or repair the affected circuit as needed.
Parts you might need
(0)Get help to fix this fault by requesting a quote