520265-03
New Holland 520265-03: CALIBRATION_SWITCH Issue: Voltage above normal or shorted to high source
Issue description
The system has detected an abnormal condition related to the CALIBRATION_SWITCH, specifically a voltage that is above normal or a short to a high voltage source.
Check the cause
CALIBRATION_SWITCH
wiring connected to CALIBRATION_SWITCH
power supply to the system
Repair steps
Inspect
Check the CALIBRATION_SWITCH for physical damage or signs of overheating.
Test
Measure the voltage at the CALIBRATION_SWITCH to confirm if it is above normal or shorted to a high source.
Inspect
Examine the wiring and connections to the CALIBRATION_SWITCH for any signs of damage, corrosion, or improper routing.
Parts you might need
(0)Get help to fix this fault by requesting a quote